Warning mail, 123 warning mail – Panasonic 616 User Manual

Page 123

Advertising
background image

123

Warning mail

The following mail will be sent to notify of a trouble occurrence to a registered address when the trouble occurs.

HD600 (192.168.0.250) STATUS REPORT
DATE: 2009-1-1 12:00:00
STATUS: The description of the trouble will be displayed. (Example: MAIN THERMAL

ERROR)

Indication

Description

DATE

Time and date when the trouble occurred will be displayed.

STATUS

The description of the trouble will be displayed.
Thermal error:
Alteration detection:
Lost of the recording area:

HDD write error detection:

HDD S.M.A.R.T. warning:

HDD remaining capacity
warning*1:

HDD hour meter warning:
Power outage detection:
Auto remove of link:

Fan error:
Copy media error:
Other errors:
HDD error:
RAID recovery failure:

THERMAL ERROR
ALTERED
"V-ERROR EVT" indicates a lost of the event recording area.
"V-ERROR NML" indicates a lost of the normal recording area.
"V-ERROR CPY" indicates a lost of the copy area.
"V-ERROR PRE-XX" indicates a lost of the pre-event recording
area (XX indicates camera channel number).
DISK ERROR XX
XX indicates disk number (sequential serial number)
DISK WARNING XX
XX indicates disk number (sequential serial number)

<except FULL>
HDD-NORMAL CAPACITY REMAINS **%
HDD-EVENT CAPACITY REMAINS **%
** indicates the set value (%) - 1
<FULL>
HDD-NORMAL IS FULL
HDD-EVENT IS FULL
HDD HOUR METER WARNING
POWER LOSS
LOGICALLY REMOVED HDD XX
XX indicates disk number (sequential serial number)
1DOWN
FAN ERROR
MEDIUM ERROR
UNDEFINED ERROR
HDD-ERROR
RAID 5 RECOVERY FAILURE X-Y
x indicates unit number, y indicates disk number

HDD remaining capacity warning
A warning mail with the <except FULL> content will be sent when the remaining disk capacity becomes less
than the set value for "HDD capacity warning" in the "Maintenance" menu. After a warning mail is sent, a warn-
ing mail with the <except FULL> content will be sent each time 1% of the remaining disk capacity is reduced,
and a warning mail with the <FULL> content will be sent when there is no remaining disk capacity.

Advertising
This manual is related to the following products: