Operation and configuration when connecting

the recorders in cascading connection

When connecting the recorders (up to 5 recorders) in cascading connection, all images managed by the con-
nected recorders can be monitored on a single monitor.
The following are descriptions of how to operate when the recorders are connected in cascading connection. To
operate the recorders connected in cascading connection, it is necessary to configure the settings in advance.
Refer to the Installation Guide for further information.

Important:

• Audio cables can also be connected in cascading connection.

Configuration

Configure the settings required for cascading connection. Operations and settings of the WJ-HD716K are the
same as that of the WJ-HD616K.

For WJ-HD616K

Select "On" for "Cascade" on the "Cascade" tab under "Display" of the setup menu of the recorder to be con-
nected in cascading connection. Set the unit addresses of recorders as follows.

WJ-HD616K

Unit address (system)

Unit address (controller)

First recorder

001

Select a number except 001 - 004 and not used
for the other devices.

Second recorder

002

Third recorder

003

Fourth recorder

004

Fifth recorder

005

Settings of a system controller

Set the unit addresses of system controllers as follows.

System controller

Unit address

Remarks

First system controller

001

It is possible to operate all monitor 1 and monitor
2 connected to the first through fifth WJ-HD616K.

Second system controller

002

Monitor 1 and monitor 2 connected to the first
through the fifth WJ-HD616K are available to oper-
ate. However, camera selection on monitor 2 is
unavailable.

Third system controller

003

Fourth system controller

004