33

Symptom

Possible cause

Remedy

Pump motor
runs, but
water flow is
inadequate

Motor is running on
the wrong voltage






Motor is running the
wrong direction

Confirm that the house wiring supply is
appropriate for the motor nameplate data.
Reconnect motor internal leads according
to the motor nameplate instructions. YOU
MUST CONTACT POWER SOAK
SERVICE OR AN AUTORIZED SERVICE
AGENCY to make these changes.

For three phase motors, reverse any two
motor leads. For single phase motors,
reconnect motor internal leads according to
the motor nameplate instructions. YOU
MUST CONTACT POWER SOAK
SERVICE OR AN AUTORIZED SERVICE
AGENCY to safely change the rotation.

Unit makes
a loud,
steady
noise when
running

Debris caught in the
motor's cooling fan






Motor seal running
dry








Debris caught in the
pump impeller

Lock and tag out the electrical power from
the unit, remove the motor fan cover, and
remove the debris. Replace the fan cover
and restore the power. For this task, YOU
MUST CONTACT POWER SOAK
SERVICE OR AN AUTORIZED SERVICE
AGENCY.

Lock and tag out the electrical power from
the unit, remove the motor fan cover, and
squirt some low viscosity oil such as WD40
between the fan and the motor end bell.
Replace the fan cover and restore the
power. YOU MUST CONTACT POWER
SOAK SERVICE OR AN AUTORIZED
SERVICE AGENCY for service of this
nature.

Lock and tag out the electrical power from
the unit. Remove the three 3/8-16 adapter
plate retaining screws adjacent to the
motor. Slide the motor, adapter plate, and
impeller out of the pump housing. Remove
debris from the impeller and reassemble.
YOU MUST CONTACT POWER SOAK
SERVICE OR AN AUTORIZED SERVICE
AGENCY for this service.