Vaddio AutoPresenter User Manual

Page 8

Advertising
background image

Auto Presenter

AutoPresenter Manual 342-0029 Rev D

Page 8 of 28

Operating the PIP:

The PIP (picture-in-picture) can be accessed via RS-232
or with the IR Remote control. For RS-232, see the
attached API in Appendix 1.

To operate the PIP with the IR remote control, perform
the following steps:

1) Chose a background input by selecting 1 through 6

on the INPUT SELECT buttons.


2) Press the PIP ON/OFF Button and then press an

INPUT SELECT button other than the input selected
as the background. The PIP will appear in the
foreground layer as a PIP.


3) To change the size of the PIP, press the PIP SIZE

button and the PIP size will cycle through three (3)
PIP sizes (small, medium & large).


4) To change the position of the PIP, press the PIP

POS button and the PIP will cycle through the
available positions clockwise.


5) To turn off the PIP press the PIP ON/OFF button

and the PIP will close.








AutoPresenter “Content Plus”
PIP Trigger Feature:
The Content Plus feature is a unique feature that allows the presenter to select background shots while
retaining the original PIP window. This works by selecting a background (like a PC input or Video White
Board) selecting a PIP input. The next input selected will momentarily move the PIP to full screen, switch
the background and then restore the PIP to the previous size and position with a different background.

AutoPresenter with Built-in PresenterPOD Support
The Vaddio Presenter Pod System (consisting of the PresenterPOD and Pod Interface) is a unique
presenter control device that employs three trigger outputs and an ultrasonic presenter sensor that allows
any presenter to easily control the content in the meeting as well as turn On/Off the PIP video within any
AutoPresenter preset.

 To assign a PIP Trigger number:

1) From the main menu scroll down until the PIP Trigger Menu is shown, touch the Select key.
2) The PIP trigger can be assigned to Triggers 1 through 24. Scroll to the number you have

selected for the PIP trigger for PIP On/Off and touch Select.

 The type or mode of the trigger can also be selected in order to work with momentary or latching

trigger products.

After selecting a PIP Trigger number:
1) From the main menu scroll to the PIP Trigger Mode and touch select.
2) Choose between the two (2) options, Momentary of Latched, and touch select.


The AutoPresenter is now configured for PIP On/Off with the trigger number assigned and the trigger type
assigned. Please see the PresenterPod and other Vaddio triggering products for additional information.

Input Select
Buttons

PIP
Controls

Figure 5:
I
R Remote

Advertising