INSTALLATION Step-by-Step Example with Codec:

This example is a room system using a Cisco C60 codec

with two (2) cameras (student camera located in front and

the instructor camera in the rear of the room). There are

18 students and 9 tables with two students to a table and

each table has a push-to-talk microphone (9 total mics)

set to momentary mode. The microphone mixer/switcher

is the Vaddio MicVIEW. The instructor has a front of the

room lectern which will be a default position and a

whiteboard area that will be covered by a Vaddio

AutoVIEW IR Sensor. Monitors are at the front of the

room. The instructor has a mic at the lectern position that

is always on - or - has a wireless lapel mic plugged into

MicVIEW Input # 1 which is always on. The equipment is

in the lectern or small rack nearby.


Step 1:

Install the videoconferencing system as described by the

system manufacturer.


Step 2:

With the codec IR remote control, set the preset

positions in the codec preset memory reflecting where

each preset position is located in the desired order that

the triggering is to be activated. In this case the Instructor

position is Preset 1 on Camera 2, the IR Sensor near the

whiteboard is Preset 2 on Camera 2 and the Students on

Presets 3 through 11 using camera 1. The presets are

stored in the codec.


Step 3:

Connect the Hot-Shot to the RS-232 Port of the TANDBERG codec, in this case with a Female to Male 9-pin

straight through RS-232 cable (PN 998-1002-232). Set the dip switches for the TANDBERG C-Series codec (first

four dip switches to Up, Down, Up, Up). Set dip switch 7 to Last Step trigger mode (Up). Set dip switch 8 to

enable Default Idle Return to activate Preset 1 (Up) so that if nothing is triggered, then the codec will return to

Preset #1 and display the instructor position. Finally, set dip switches 9 and 10 (both Up) to Hot-Shot Address

Master 0, since only one Hot-Shot is being used.


Step 4:

Connect the IR Sensor leads (+ to connector 2 and - to GND) to the Hot-Shot. Connect the MicVIEW logic out

triggers 3 through 11 to terminals 3 through 11 on the Hot-Shot and the GND wire of the MicVIEW to the GND of

the Hot-Shot. Leave Terminal 1 of the Hot-Shot empty since Default Idle Return to Preset 1 is on and is the

Instructor on Preset 1 of the codec.


Step 5:

Once all the presets have been saved, and the trigger connections made, then power down the system

completely. To reboot the system, turn on the Hot-Shot, and then turn on the codec. The system should be

ready for use. Test each trigger and fine tune the camera presets as needed.


Notes:

To use the videoconferencing system without triggers, simply touch the blue LED button on the front panel of the

Hot-Shot to disable the triggers/presets. When the Blue LED is off, the preset triggers are disabled.

The camera presets are stored in the codec and can easily be overwritten by users that are unfamiliar with the

room automation set-up. Please keep a record of the preset numbers and locations available to quickly

reprogram the codec if some of the presets are inadvertently erased or changed.

Mics x 10

Lectern

Whiteboard

(P2)

Instructor

Camera (2)

Student

Camera (1)

Displays

IR

Sensor

Instructor

Position (P1)

P3

P5

P4

P7

P6

P1

0

P8

P9

P1

1

Basic Hot-Shot Room Example with Codec