Unpacking:

The 999-1105-022 System is Packaged as a Worldwide* Product and Includes:

 One (1) 998-1105-022 CCU Image Controller for CeilingVIEW HD-18 DocCAM

 One (1) 12 VDC, 1.0 Amp Switching Power Supply

 One (1) North American AC Cord Set

 One (1) Euro AC Cord Set

 One (1) UK AC Cord Set

 One (1) Manual
*Worldwide Packages contain North American and International Power Cords

CCU Image Controller Front Panel Controls (left to right):





Tally Light:
The blue LED tally light on the front panel is tied to the tally contacts on the rear panel allowing the user to easily track
which CCU is being used in a multi-camera system by supplying a simple contact closure (i.e. from ProductionVIEW
Precision Camera Controller or ProductionVIEW HD).

LCD Display:
Backlit (blue) display indicates which parameter (iris, detail, etc.) is being adjusted. When a rotary encoder is moved,
the name of the control being adjusted and the value of that assigned parameter will be displayed.

Scenes A, B & C:
Three camera adjustment scenes (A, B & C) can be stored into microprocessor memory. When lit (backlit blue SPDT
button), the scene is activated. To store a scene, the user adjusts the controls and touches and holds the scene button
down until the button blinks.

Detail:
The Detail control sharpens or softens objects in the frame.

Red & Blue Gain Controls:

The Red and Blue Gain encoders adjust the red and blue gain of the signal when AWB is disengaged.

AWB:

The Automatic White Balance controls/adjusts the color levels automatically when engaged. Turn off AWB to manually
adjust the Red and Blue levels, as well as Red, Green and Blue Enhance.

SHIFT:

Pressing Shift illuminates the button and changes the Pedestal adjustment knob to Knee adjustment. Knee adjustment
allows bright objects that are easily overexposed to be reproduced more accurately. Pressing the Shift button a second
time turns the light off, and the knob reverts to Pedestal adjustment.

Pedestal / Knee, Chroma & Gamma:

The Pedestal adjustment controls the absolute black level of an image. Chroma controls the overall color of the image
being captured. Gamma adjusts the overall brightness of an image. See SHIFT for information on Knee.

Auto Iris:
The Auto Iris mode automatically adjusts the iris and gain of the camera. To manually adjust the iris or gain, turn off this
control.

Manual Iris:
The Manual Iris control allows the user to set the iris manual to one of the 18 settings available.

Gain:
The Gain control boosts the signal level when the iris is open all the way, and there is not enough lighting available. To
manually adjust the Gain, Auto Iris must be off.