Step 6:
Attach the PrecisionHD camera to the mount with the provided ¼” x 20 screw, tie up the cables neatly and
connect the Cat-5e cable from the head end to the connector labeled OneLINK as shown below.























Step 7:
At the head end, connect the Cat-5e cable from the camera location to the OneLINK port on the Quick-Connect
OneLINK port as shown above.

Step 8:
From the Quick Connect OneLINK, connect the HDMI output to the desired codec input. Use the provided 9-Pin
RS-232 to RJ-45 adapter to connect the camera control port on the codec to the camera control port on the
OneLINK with a Cat-5e cable as shown below.

Do not use the Cisco/TANDBERG DB-9M to RJ-45 Cable #

116627 to make this connection.
























OneLINK Cat-5e

Up to 125’ (38.1m)

Camera

Location

Head End Location

Cat-5e Patch Cable

(Not Supplied)

Do not use the

Cisco/TANDBERG

Cable # 116627 to

make this connection

HDMI Cable

(Not Supplied)

Provided RS-232 to

RJ-45 Control Adapter

(Camera Control Port)

RS-232

Cat-5e not

provided

Cisco C60

Do not use cable
#116627 supplied
with the codec on
this Camera Control
Port