Replacement parts – Woodhead BF Series User Manual

Page 3

Advertising
background image

SM1120-01 E

Page 3 of 4

©Aero-Motive Company Sep-01

CABLE REPLACEMENT

CAUTION:

Do not disassemble balancer without reducing all spring tension first. (See Spring
Tension Adjustment).
Also, do not adjust mainspring tension until tool and attachments
are suspended from balancer. Hazards or unsafe practices COULD result in minor
personal injury or product or property damage.

To replace cable, remove balancer from service and remove all
spring tension from balancer. (See Spring Tension Adjustment).
Remove two screws at cable guide, four (4) screws and nuts.
Remove case rear assembly, auto stop shaft, auto stop with
compression spring, and cable assembly. Remove cable guide,
bumper, cable-stop, hex nuts, machine screw and tool clip from
old cable assembly. Attach these items to the new cable
assembly. Place the swaged cable assembly end into the slot.
Reassemble unit in reverse order. Place balancer back in service
and attach tool. (See Tool Attachment). Set spring tension. (See
Spring Tension Adjustment)

PARTS REPLACEMENT

NOTE: When ordering replacement parts, always include the balancer model number and serial number.

All parts shown on parts list are replaceable in the field without special tools.

MAINTENANCE INSPECTION

The balancer is designed to require little maintenance. Periodically check cable, tool clip, swivel, and
hanger for wear. Replace all worn parts immediately. The balancer is lifetime lubricated at the factory.
No additional lubrication is required.

REPLACEMENT PARTS