CANopen USER GUIDE

Beijer Electronics Automation AB

PAGE 1

BFI-P2 CANopen Manual

Author:

Ning Xu

Date:

6

th

February 2012

Revision:

1.10

General:

The CANopen communication profile in the P2 drive is implemented according to the specification DS301

version 4.02 of CAN in automation (

www.can-cia.de

). Specific device profiles such as DS402 are not supported.

Operation Setup:

The CANopen communication function is enabled by default after power up. However in order to use any

control functions through CANopen, user has to set drive parameter P1-12=6.

The CAN communication baud rate can be set by using parameter P5-02. Available baud rates are:

125kbps, 250kbps, 500kbps, 1Mbps. (with default settings as 500kbps)

The Node ID is set up through drive address parameter P5-01 with a default value of 1.

The RJ45 socket is used as CAN signal physical connector with the signals layout as shown blow:

Optidrive P2 provides the following default COB-ID and functions:

Table 1 : Messages and COB-IDs

Type

COB-ID

Function

NMT

000h

Network management

Sync

080h

Synchronous message

COB-ID can be configured to other value.

Emergency

080h + Node address

Emergency message

COB-ID can be configured to other value.

PDO1 (TX)

180h + Node address

PDO1 (RX)

200h + Node address

PDO2 (TX)

280h + Node address

PDO2 (RX)

300h + Node address

Process data object.

PDO1 is pre-mapped and enabled by default.

PDO2 is pre-mapped and disabled by default.

Transmission mode, COB-ID and mapping can be configured.

SDO (TX)

580h + Node address

SDO (RX)

600h + Node address

SDO channel can be used for drive parameter access.

Error Control

700h + Node address

Guarding and Heartbeat function are supported.

COB-ID can be configured to other value.

Note:

1.

The Optidrive P2 SDO channel only supports expedited transmission.

2.

The Optidrive P2 can only support up to 2 Process Data Objects (PDO). All PDOs are pre-mapped, however

PDO2 is disabled by default. Table 2 gives the default PDO mapping information.

3.

Customer configuration (mapping) will

NOT

be saved during power down. This means that the CANopen

configuration will restore to its default condition each time the drive is powered up.

1: CANopen -

2: CANopen +

3: 0V

4: RS485- (Optibus)

5: RS485+ (Optibus)

6: +24V

7: RS485- (Modbus)

8: RS485+ (Modbus)