Beijer Electronics BFI-P2 v1.10 User Manual

Page 6

Advertising
background image

CANopen USER GUIDE

Beijer Electronics Automation AB

PAGE 6

2321h

0

P8-01

RW

-

N

2000h + 801d

Group 8 parameters

RW

-

N

232Fh

0

P8-15

RW

-

N

2000h + 815d

2385h

0

P9-01

RW

-

N

2000h + 901d

Group 9 parameters

RW

-

N

23ADh

0

P9-41

RW

-

N

2000h + 941d

23E8h

0

Scope index 12

RW

-

N

2000h + 1000d

23E9h

0

Scope index 34

RW

-

N

2000h + 1001d

Drive Specific Object Reference:

Object

2000h : Control command register

2000h Control Command Register

Bit 15 ~ Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Reserved

Coast stop

Reset

Fast stop

Run

If bit 0 is set, the drive will start to run provided that specified condition is met.

If bit 1 is set, the drive will carry out a fast stop. This bit will override the run bit if set

If bit 3 is set, the drive will carry out a coast stop. This bit will override the run and fast stop bits if set.

Bit 2 is used to reset the drive under trip conditions. This reset function is edge active (0

1)

Object

2001h : Speed reference (Hz)

The data value of this object provides the speed reference in Hz format. Data includes once decimal place.

For example, a data value of 500 equates to a speed reference of 50.0Hz. Similarly, a data value of 125

equates to a speed reference of 12.5Hz. If the data value is set to -1234 (0xFB2E), the speed reference will be -

123.4Hz.

Object

2002h : Torque reference (%)

The data value of this object provides the torque reference as a percentage. The data includes one decimal

place. For example, a data value of 500 equates to a torque reference of 50.0% of the motor rated torque. If

the data value is 1250, the resulting torque reference will be 125%

Object

2003h : User ramp reference (0.01s)

The data value of object this set the user ramp time. Value contains two decimal places.

For example, if the data value is 30, the resulting user ramp time will be 0.30s. If data value is 1234, the

resulting ramp time will be 12.34s

Object

2004h : Speed reference (IDL internal format)

The data value of this object provides the speed reference in IDL internal data format. This provides a higher

resolution control result.

If the motor base frequency <= 100Hz, data value 3000 means the speed reference is set to 50Hz.

If the motor base frequency <= 200Hz, data value 3000 means the speed reference is set to 100Hz.

If the motor base frequency > 200Hz, data value 3000 means the speed reference is set to 200Hz.

Advertising