BATTERY STATUS

Indicates the power remaining in the transmitter

battery. When the battery has less than 10% power

remaining it must be replaced or recharged. If an

under voltage condition continues, the LCD will show

“Poff” and the system will shut down to prevent

being overly discharged.

“Poff” - Power Off :

100%

80%

40%

10%

0%

5

6

When the power switch is turned off, the LCD will

show “Poff” (for Power Off) first and then the system
will shut down and no further messages will be
displayed.

ERR

GROUP CHANNEL BAT

LCD SCREEN

!

ERR Message: When “ERR” appears in the display

it indicates that an operational error has occurred.

Please refer to the following codes to diagnose

which error you are experiencing.

ERR no01 EEPROM is not being programmed or internal

data error.

ERR no02 For testing only.

ERR no03 The frequency you want to program is above

the switching bandwidth of the transmitter.
Use a receiver with an appropriate frequency
group. (At this time the microphone is still
operating and the frequency remains
unchanged. To clear the displayed "ERR"
message, switch the handheld transmitter off
and on again.)

ERR no04 The frequency you want to program is below

the switching bandwidth of the transmitter.
Use a receiver with an appropriate frequency
group. (At this time the microphone is still
operating and the frequency remains
unchanged. To clear the displayed “ERR”
message, switch the handheld transmitter off
and on again.)

!

“Group” & “Channel” : When both the group

and channel numbers are displayed, it means that

you are using the pre-programmed frequency of

the receiver.

!

“Channel” Only: If “Channel” only is displayed, it

means that you are using a frequency which is not

pre-programmed.