ATTACHING HOSE

To use the machine with the vacuumated tools use the following instructions. Insert the vacuum
hose (15) into the vacuum hose outlet (7) and the steam plug (17) into the steam outlet (20)
found on the front of the machine. Both fittings lock into place. It is recommended that hoses be
fitted to the machine before turning the boiler ON.

D)

BOILER ACTIVATION

Activate the boiler switch (11) and the steam/vacuum command switch (12). The handle
control switches (25 and 26) should be in the OFF position. When the water is heated to
operating temperature the green ready steam indicator (10) will light.

E)

STEAM ACTIVATION

When the unit has reached operating temperature, steam will issue from the machine when the
steam command switch (26) is turned ON. When the tools are cold, water caused by internal
condensation will issue from the nozzle before the steam. Steam volume can be regulated by
turning the steam volume knob (13) clockwise for minimum volume and counter-clockwise for
maximum steam. If the steam volume knob is turned all the way closkwise, the flow of steam
will be cut off.

F)

VACUUM ACTIVATION

To set the vacuum up for operation, verify that the ON/OFF switch (2) on the vacuum unit (1) is
in the ON position. To turn the vacuum ON while the machine is in steam operation, turn the
vacuum command switch (25) ON.

NOTE:

When the vacuum is turned on while steam command switch is on, power input

to the boiler is reduced. For this reason is best to turn the steam command switch OFF before
activating the vacuum. This will help maintain high steam pressure and temperature for best
cleaning results.

G)

ATTACHING ACCESSORY TOOLS

Note:

Steam and vacuum command switches (25 and 26) should be in the OFF position

when changing tools.

Floor Tool (42)

The multi-purpose floor tool has 2 inserts (45 and 46) which may be inserted for different
cleaning applications. Inserts are locked in place by sliding the red lock/release latches (43) in,
pushing the insert into place and then sliding the lock/release latches out again.

Suction Nozzle (51)

The suction nozzle can be used by itself or with the upholstery nozzle (50).

Extension Tubes (41)

Extension tubes can be used if necessary. These attach directly to the hose assembly and then to
either the floor tool or suction nozzle. Extension tubes lock into place by sliding the latch (40).