NaceCare Solutions SNTD750 User Manual

Page 3

Advertising
background image

3

When very heavy material is to be recovered, an optional permanent Permatex bag with
heavy duty lifting handles can be ordered (NVM 32F). It is recommended to use open
paper bags as a liner with the permanent Permatex bag as the main collection filter.

Filter Cages

Within the lower tank of the machine are 2 filter cages. On the base of the tank is a
circular cage which supports the main filter cage. The main filter cage is used to keep
the chosen filters away from the sides of the lower tank. This maintains airflow around
the filters at all times, allowing the full capacity of the vacuum to be utilized.

Recovery Tank

The recovery tank has a transfer hose screwed onto the back. This hose is in turn
atached to the back of the special cyclonic assembly. On the front of the recovery tank
is a intake port with a chrome blanking cap. This should not be removed.

Transport Chassis

The recovery tank is supported by a 4-wheeled stainless steel chassis. This will carry
the full weight of the machine and recovered debris. The front of the chassis has a
horizontal bar with two punched holes in it. This is to allow wide area wet or dry
cleaning kits to be fitted to the machine. The machine body is attached to the chassis
with a steel toggle. It can be removed from the chassis by lifting up the toggle.

Accessories

The is equipped with our standard intake fitting, allowing all 1 1/2" and 2" Numatic
accessories to be used. It is NOT recommended to use any of the 1 1/4" accessories as
this substantially reduces the airflow performance of the machine

WARNINGS

If used for any potentially hazardous or health endangering material recovery, do not
use the machine unless the full filtration system is fitted. Failure to fit the complete
system may cause premature clogging of the HEPA filter cartridge and may also
endanger health.

Do not use the machine in corrosive or flammable environments.

Do not use this machine for the collection of explosive dusts.

When operating the machine in contaminated environment, always use protective
respiratory equipment and suitable approved personal protective clothing.

Advertising