UNPACKING AND SETUP OF THE MACHINE (CONT’D)

4. Remove the 4 allen screws holding the grey cover to the frame.
5. Remove the cover to expose the battery compartment as shown in Fig 2 below.

Fig 1

Fig 2

6. Once the cover is removed, you must connect the battery cables to the battery. When

connecting the battery terminals, do not reverse the polarity. Ensure that the red wire goes to
the + terminal and the black wire goes to the – terminal on the battery.


NOTE: If the polarity of the battery cables is reversed, the battery and charger can suffer severe
damage. The battery connection may only be made by qualified personnel.

NOTE: Once the battery connection is made, the machine will not run until the cover and 4 allen
screws are back in place. This is done as a safety precaution to prevent bodily injury from the rotating
belts and motors. DO NOT try to override this safety feature.

MAIN AND SIDE BROOM ADJUSTMENTS

MAIN BROOM ADJUSTMENT

The main broom adjustment is located on
either side of the machine as indicated by
the arrow on the figure to the right. To
adjust the height of the main broom, pull
on the knob and move the slider up or
down. This adjustment must be the same
on both sides as the main broom must be
level while operating.