Fault finding, Dry mode, Wet mode – NaceCare Solutions WV800 User Manual

Page 12: Data, This machine can be used for wet and dry pick up, Motor airflo suction cleaning range class

Advertising
background image

Motor

AirFlo

Suction

Cleaning

Range

Class

CVC 370

WV 370

WV 470

1200W

1200W

1200W

40 L/sec

40 L/sec

40 L/sec

2500 mm

2500 mm

2500 mm

28.8m

28.8m

28.8m

II

Capacity

Dry

Capacity

Wet

Size

Weight

Sound

Pressure

CVC 370

WV 370

WV 470

15 Ltrs

15 Ltrs

27 Ltrs

9 Ltrs

9 Ltrs

20 Ltrs

355x355x510

355x355x510

355x355x710

7.1 Kgs

7.1 Kgs

9.6 Kgs

73-77 dB

(IEC 60704-2-1)

Uncertianty: 0.2 dB (A)

Fault Finding

This machine can be used for wet and dry pick up.

Dry Mode

If the vacuum cleaner stops working switch off and remove the plug from the wall before

investigating were the fault lies.

If the vacuum cleaner will not pick up any debris from the surface, switch off and remove the plug from the wall,

inspect the floor tool, wands and hose for blockages, if no blockages are found, the dust bag may be full if the

dust bag is not full the filter may be blocked.

Wet Mode

If the vacuum cleaner stops working switch off and remove the plug from the wall before investigating were the

fault lies.

If the vacuum cleaner has a blockage and will not pick up liquid, switch off and remove the plug from the wall,

has the float valve operated, this will shut off the suction and the pitch of the vacuum motor will change Remove

the power head and empty the liquid out of the container, if the container is empty, check that the floor tool

wands and hose are not blocked.

After use always inspect the machine for damage.