En 30 31, Option b: replace the whole cartridge, Replacement of the demineralization cartridge – Air-O-Swiss AOSU600 User Manual

Page 16: Option a: replace the granules

Advertising
background image

16

en

30

31

• Turn the plastic cup and cartridge over and shake until

all granules are in the cartridge (37).

• Remove the plastic cup and the pink styrofoam piece

from the cartridge (38) and retain for future use (the

refill granules consists of 3 refill bags) (39).

• Close the cartridge (40).

• Soak the demineralization cartridge in a water bath

24 hours before using it (43). The granules have to ab­

sorb water to reach high performance. If the cartridge

is soaked in the tank, make sure to exchange the water

and empty the water from the base before using the

humidifier.

• Screw the cartridge on the water tank cap (44).

• Screw the cartridge on the bottom side of the water

tank, put the tank on the main body (45).

Placing granules in the center of the cartridge

allows them to escape in the unit or to clog the

unit. The unit will no longer operate properly and

the granules need to be cleaned out thoroughly.

Option B: replace the whole cartridge

• Remove the water tank from the base and unscrew the

water tank cap (30).

• The demineralization cartridge is attached to the tank

cap. Unscrew the cartridge from the cap by turning it

counter­clockwise (31). Important: do NOT dispose of

the water tank cap!

• Throw the whole cartridge into the waste (41).

• Unpack the new cartridge (42).

• Soak the demineralization cartridge in a water bath

24 hours before using it (43). The granules have to ab­

sorb water to reach high performance. If the cartridge

is soaked in the tank, make sure to exchange the water

and empty the water from the base before using the

humidifier.

• Screw the cartridge on the water tank cap (44). Close

tank cap well and place the tank on the main body

(45).

Replacement of the demineralization

cartridge

Always unplug the unit before removing the

water tank. Do not touch the water in the base

during operation!

The water tank is equipped with a demineralization cart­

ridge. This cartridge has to be replaced every 2 – 3 months.

If the water is very hard, it may be necessary to replace the

cartridge earlier. White dust around the device is a sure sign

that the cartridge needs replacing. If white residue still forms

around the device after a new cartridge has been inserted,

please make sure that the water you are using is untreated.

If the water flows through a decalcification system – such as

an ion exchanger – (sodium is added to remove calcium) in

the building before it is used in the humidifier, salt can pre­

cipitate as white dust around the device. The demineralization

cartridge or the granules must be exchanged at the latest

after 6 months or the unit does not reach its full performance

anymore.

Option A: replace the granules

• Remove the water tank from the base and unscrew the

water tank cap (30).

• The demineralization cartridge is attached to the tank

cap. Unscrew the cartridge from the cap by turning it

counter­clockwise (31). Important: do NOT dispose of

the water tank cap!

• Open the cartridge (32).

• Throw the content into the waste (Attention! Disposed

granules can make the floor slippery!) (33).

• Place the enclosed pink styrofoam piece in the center

of the cartridge. Do not push it to the bottom as it will

be difficult to remove afterwards (34).

• Pour the contents of one refill granules bag into the

plastic cup that is included with the refill granules pa­

ckaging (35).

• Place the empty cartridge with the plug in the center

onto the plastic cup (36).

32

33