SPECIFICATIONS

MYRON L

®

COMPANY

2450 Impala Drive • Carlsbad, Ca 92010-7226 • Phone: +1-760-438-2021

E-Mail: Customer Service – [email protected] • Technical Support – [email protected]

Website: www.myronl.com

MADE IN USA

©2014 MYRON L

®

COMPANY

Do not over tighten.

App Requirements:

Apple iOS 6 or iOS 7. Optimized for iOS 7.

Measurement Range:

0.00 – 14.00 pH; Temperature: 0°-71° C/32-160° F

Accuracy (After Wet Calibration):

± 0.01 pH; Temperature ± 0.1ºC / ± 0.1ºF

Repeatability:

± 0.01 pH; Temperature ± 0.1ºC / ± 0.1ºF

Resolution:

0.01 pH; Temperature ± 0.1ºC / ± 0.1ºF

Time to Reading Stabilization:

10 - 30 seconds

Active Mode Power Consumption: Active Mode 137 mA, Sleep Mode 2 µA
Temperature Compensation:

Automatic to 25ºC

Physical Dimensions:

17.15 cm L x 1.59 cm D or 6.75 in. L x .625 in. D

Weight:

54 g or 1.94 oz

Case Material:

Anodized Aircraft Aluminum with Protective Coating

Battery Type:

N type, Alkaline 1.5 V

Calibration Standard Solution:

4.0 pH, 7.0 pH, 10.0 pH

Operating/Storage Temperature:

0 - 55ºC / 32 - 131ºF

Water Resistance:

IP67 and NEMA 6

EN61236-1: 2006 - Annex A:

2008; 1999/5/EC Annex III

Electrostatic discharge to case of instrument may

cause PTBT2 to spontaneously power on. In this case,

the PTBT2 will power off after several seconds

FCC ID: T7VPAN17

The Bluetooth transceiver device meets the requirements for

modular transmitter approval as detailed in FCC public Notice

DA00-1407.

Canada (IC), license:

IC: 216Q-PAN17

The Bluetooth transceiver device meets the requirements for

modular transmitter approval as detailed in RSS-GEN.

ORIGINAL

EDITED FOR USE

Minimum height 5 mm

QUICK REFERENCE INSTRUCTIONS

1. Turn on ULTRAPEN App: Tap ULTRAPEN icon on mobile device’s home screen.

2. Turn on PTBT2: Press and release push button on pen.

3. LED flashes rapidly: Dip pen in sample solution so cell is totally submerged.

4. LED flashes slowly: Swirl pen to remove bubbles, keep cell submerged.

5. LED turns solid ON then turns OFF: Measurement is complete and reading is displayed.

Feature Navigation Bar

This button always returns the App to the Measurement Screen.

This button displays a list of saved measurements.

This button places the App in Calibration mode.

This button opens the App’s Bluetooth Connect / Disconnect screen.

This button opens the App’s preferences and settings mode.

An internet link to full Operations Manual (Help button) is found here.

ACCESSORIES

STANDARD SOLUTIONS FOR CALIBRATION: The ULTRAPEN™ PT2 requires pH 4, pH 7, and pH 10

buffer solutions for wet calibration and pH Sensor Storage Solution for proper storage.

— Order MODEL#s: PH4, PH7, PH10, and PHSS.

Replacement pH Sensor (with instructions) — Order Model: RPT2

.

III. pH Sensor Replacement

(Follow the instructions that come with your Replacement Sensor.)

Only Remove/Replace the pH sensor in a CLEAN and DRY environment!

To remove the pH sensor:

1. Remove the soaker cap; make sure the PTBT2 (including the pH sensor) is clean

and dry. Loosen the battery tray to allow pressure equalization.

2. Then firmly grasp the pH sensor body and slowly pull the pH sensor out.
To install a new pH sensor:

1. Line up the alignment tabs on the pH sensor with the alignment slots on the PT2

unit.

2. Gently push the pH sensor into position, close battery cap.

CAUTION:

MYRON L

®

WARRANTY

Excepting sensor and battery, the Myron L

®

Company PTBT2 pH ULTRAPEN is war-

ranted to be free from manufacture defect for 1 year. The pH sencer has a six (6) month

limitted warrenty.