Installation – Magikitch'n MKE Electric Griddle User Manual

Page 7

Advertising
background image

Installation

MKE Series Electric Griddle

L20-369 REV. 2 (05/12)

7

1.1. ELECTRICAL CONNECTIONS
It is advised that this power supply be plugged into a wall receptacle or hard wired into a circuit that is
controlled by the ventilation control. This will prevent the appliance from being operated without the
ventilator on.

Have qualified professional connect the power supply to the terminal block(s), if a cord is not supplied,

according to their labeled leg (L1, L2, L3, ground and N as applicable). Access to the terminal blocks can
be gained by first removing the grease drawer, then removing the lower rear and front panels (order of
removal is shown in figure 7). This will require a Phillips head screwdriver and a 5/16 nut driver, wrench or
ratchet. Minimum gauge copper wire is noted on the data plate.
























WARNING

This appliance must be connected to a power supply having the same voltage and phase as
specified on the data plate located on the wall inside the grease drawer chute.

WARNING

DO NOT attempt to connect the appliance to an electrical supply other then that indicated
on the data plate. Electrical connection should be performed by qualified personnel.

WARNING

The electrical connection used by this appliance must comply with local codes. In the US, if
there are no local codes that apply, refer to the National Electrical Code (NEC), ANSI/NFPA
70 for installation in the US. In Canada, refer to CSA Standard C22.2 and local codes. In all
other cases, refer to local and national codes and regulations.

WARNING

The appliance must be grounded in accordance with local code; in North America, if there is
no local code, comply with the NEC and ANSI/NFPA No. 70 latest edition (for US and
Canadian installations). In all other cases, refer to local and national codes and regulations.
To comply with European requirements, European models are equipped with an
equalization-bonding clamp. An equalization bonding lead must be connected to this clamp
to provide sufficient protection against potential difference. This clamp, located on the rear
of the appliance is marked with the following universal symbol.

WARNING

A country approved all pole circuit breaker with a minimum open contact gap of 3mm must
be used for proper installation. (CE countries)

Figure 6

Figure 7

CAUTION

Connecting the appliance to the wrong power supply may damage the appliance and void
the warranty.

Advertising