4. GAS SETTINGS

 

Regulator pressure must be measured and adjusted before the unit goes into
service, following installation and when operational performance is in question. A
soft blue flame, just short of a yellow tip, gives the best results; combustion air can
be adjusted by opening or closing the air shutter slightly.

5. LIGHTING INSTRUCTIONS

 

A. FOCUS SERIES MODELS WITHOUT SAFETY PILOT

 

1. Turn all burners to OFF. 
2. Remove the top grid(s). 
3. Remove the last radiant(s) closest to the side(s) of the unit. 
4. Turn the runner tube valve to ON. 
5. Light the runner tube. 
Note: If runner tube does not light wait a few seconds, then try again. 
6. Replace the radiant(s) and top grid(s).  Push and turn the burner valves to operate the 

individual burners as needed. 

7. If any burner fails to light from runner tube, shut off all the burners and the runner tube. DO 

NOT attempt to re‐light for five minutes after shutdown. Repeat steps 1 thru 6. If unit still 
fails to operate properly, contact authorized service personnel. 

 

 

 

 

 

 

 

 

BROILER SHUT DOWN 

Turn all burners to OFF. 
Turn the runner tube valve to OFF. 

 

 