7. OPERATION, LIGHTING and CLEANING

 Assemble unit per installation and assembly instructions.
 Fill water tubs to within ½” of top edges (this will control grease flare-ups, provide for ease of cleaning and

keep cooked foods moist). Re-fill tubs with water when they evaporate to within ½” of the bottom of the
tubs. Failure to keep water in the water tubs will lead to grease fires and will void the warranty.

Lighting Instructions

A. Check that the side tank racks are securely mounted on the unit.

B. Open the cooking hood, if so equipped. Turn all the burner knobs and red runner tube knobs clockwise to

the ‘off’ position, and slowly open the gas tank valves.

C. Push & turn the runner tube knob(s) fully counter-clockwise to the ‘on’ position. Insert a lit match with the

matchstick holder or a gas lighter flame through the oblong hole in the front panel.

D. Check that the entire runner tube is lit by looking through the sight hole(s) located between the end burner

knobs on the front panel. If the runner tube(s) will not light or stay lit, shut off the gas supply and do not
use the unit. Wait 5 minutes before attempting to re-light the unit.

E. After lighting the runner tube(s), open the desired burner valves and observe that the burners light

completely from the runner tubes(s).

Warning: If the burners or runner tube(s) fail to light or remain lit, shut off and disconnect the gas supply
tank(s) and discontinue use of the unit. Call for service to correct the problem.

NOTE: If the tank valves are not opened very slowly, an excess flow valve in the tank connector fitting (a safety
feature) may restrict the flow of gas to the unit resulting in little or no flame at the burners. Should this happen,
follow the shutdown instructions and be sure to shut off tanks and remove and re-attach the tank connectors as
instructed. This is necessary to re-set a closed excess flow valve. Repeat steps A through E of the lighting
instructions. The appliance should now function normally. Failure to follow these guidelines may cause the
excess flow valve to restrict gas flow.

Shutdown Instructions

 To shut down the unit, turn all burner and runner tube knobs clockwise to the ‘off’ position. Close gas tank

valve(s), disconnect propane tank(s) and leave them outdoors.