14. Remove mechanical seal (383).
NOTE: For complete pump disassembly,
continue with removal of seal
chamber/adapter.
REMOVAL OF SEAL CHAMBER/ ADAPTER-
S GROUP (1 x 1
1
2
- 6, 1 x 1
1
2
- 8, 2 x 3 - 6)
15. Remove motor-mounting hex cap screws
(370U) (Fig. 15).
16. Remove seal chamber/adapter (184)(Fig. 16).
▲
!
CAUTION
Be careful not to damage stationary portion of
the mechanical seal.
17. If required, remove mechanical seal stationary
seat.
REMOVAL OF SEAL CHAMBER - M GROUP
(2 x 3-8, 1 x 2-10, 2 x 3-10)
18. Remove seal chamber hex cap screws (370B).
19. Remove seal chamber(184) (Fig. 17).
▲
!