POST ASSEMBLY CHECKS

After completion of these operations, check if it is possible to rotate shaft easily by hand. If all is proper, continue
with pump start-up.

ASSEMBLY TROUBLESHOOTING

34

3100 IOM 1/97

Symptom

Cause

Remedy

Excessive frame adapter runout.

Corrosion.

Replace frame adapter.

Excessive seal chamber runout.

Seal chamber not properly seated
in frame adapter.

Reseat seal chamber.

Corrosion or wear.

Replace seal chamber/stuffing box
cover.