Post assembly checks, Assembly troubleshooting – Goulds Pumps 3100 - IOM User Manual
Page 42
Advertising
Table 7
Torque Values for Case Mounting
Hex Cap Screws and Nuts
Pump Sizes
Torque (ft. - lb.)
1 x 1
1
2
-6
20
2 x 3-6
20
1 x 1
1
2
-8
59
2 x 3-8
59
1 x 2-10
59
2 x 3-10
59
POST ASSEMBLY CHECKS
After completion of these operations, check if it is possible to rotate shaft easily by hand. If all is proper, continue
with pump start-up.
ASSEMBLY TROUBLESHOOTING
34
3100 IOM 1/97
Symptom
Cause
Remedy
Excessive frame adapter runout.
Corrosion.
Replace frame adapter.
Excessive seal chamber runout.
Seal chamber not properly seated
in frame adapter.
Reseat seal chamber.
Corrosion or wear.
Replace seal chamber/stuffing box
cover.
Advertising