Goulds Pumps AF (Axial Flow) (42"/1200mm/54/60"/66") LM/LMR Bearings - IOM" User Manual

Page 24

Advertising
background image

24

AF (42-66) IOM

1.

Mount two dial indicators off one half of the

coupling (X) so they contact the other coupling half (Y)
(Fig. 15).


2. Check setting of indicators by rotating coupling
half (X) to ensure indicators stay in contact with
coupling half (Y) but do not bottom out. Adjust
indicators accordingly.

MEASUREMENT


3. To ensure accuracy of indicator readings, always
rotate both coupling halves together so indicators
contact the same point on coupling half (Y). This will
eliminate any measurement problems due to runout
on coupling half (Y).

4. Take indicator measurements with hold-down bolts
tightened. Loosen hold down bolts prior to making
alignment corrections.

5. Take care not to damage indicators when moving
driver during alignment corrections.

Keep this instruction manual handy for reference.
Further information can be obtained by contacting
Goulds Pumps, 240 Fall St., Seneca Falls, New York
13148 or your local representative.

ALIGNMENT PROCEDURE

On gear driven AF pumps angular and parallel
misalignment are corrected in the vertical direction by
means of shims under the motor or gearbox mounting
feet, and in the horizontal direction by adjusting bolts
that slide the motor or gearbox in the proper direction.

After each adjustment, it is necessary to recheck the
alignment of the coupling halves. Adjustment in one
direction may disturb adjustments already made in
another direction. It should not be necessary to adjust
the pump in any way.

ANGULAR ALIGNMENT

Couplings are in angular alignment when indicator “A“
(Angular Indicator), Fig 15, does not vary by more than
.003” (.076mm) as measured at four points on the
coupling periphery 90

° apart at operating temperature.

Outlined below are two acceptable methods to achieve
the desired alignment.


METHOD 1 - Dial Indicator Method

For steps 1 through 5 refer to Fig. 16 on the following
page.

1. Zero indicator “A” at position 1 of coupling half (Y).

Mark this position on both flanges.


2. Rotate both flanges 180

° to position 3. Observe

needle and record reading.


3. Negative Reading - The coupling halves are

further apart at position 3 than position 1.

Positive Reading - The coupling halves are closer
at position 3 than position 1.

Fig. 14

Fig. 15