These are the personnel requirements for Ex-approved products in potentially explosive atmospheres:

• All work on the product must be carried out by certified electricians and ITT-authorized mechanics.

Special rules apply to installations in explosive atmospheres.

• All users must know about the risks of electric current and the chemical and physical characteristics of

the gas and/or vapor present in hazardous areas.

• The maintenance operation for Ex-approved products must be made in conformity to the

international or national standards (IEC/EN 60079-17).

Product and product handling requirements

These are the product and product handling requirements for Ex-approved products in potentially
explosive atmospheres:

• Only use the product in accordance with the approved motor data stated on the nameplates.
• The Ex-approved product must never run dry during normal operation. Dry running during service

and inspection is only permitted outside the classified area.

• Never start a pump without the proper priming.
• Before you start working with the product, make sure that the product and the control panel are

isolated from the power supply and the control circuit, so they cannot be energized.

• Do not open the product while it is energized or in an explosive gas atmosphere.
• Make sure that thermal contacts are connected to a protection circuit according to the approval

classification of the product.

• Intrinsically safe circuits are normally required for the automatic level-control system by the level

regulator if mounted in zone 0.

• The yield stress of fasteners must be in accordance with the approval drawing and the product

specification.

• Make sure that the equipment is properly maintained:

• Monitor the pump components and the end temperature of the liquid.
• Maintain proper bearing lubrication.

• Do not modify the equipment without approval from an authorized ITT representative.
• Only use parts that have been provided by an authorized ITT representative.

Equipment for monitoring

For additional safety, use condition-monitoring devices. Condition-monitoring devices include but are not
limited to these devices:

• Pressure gauges
• Flow meters
• Level indicators
• Motor load readings
• Temperature detectors
• Bearing monitors
• Leak detectors
• PumpSmart control system

Product approval standards

Regular standards

All standard products are approved according to CSA standards in Canada and UL standards in USA. The
drive unit degree of protection follows IP68. See the nameplate for maximum submersion, according to
standard IEC 60529.
All electrical ratings and performance of the motors comply with IEC 600341.