Model ICM/ICMP,

for life

grease lubrication


9330-050-en

Revision 05

TM 5409 MPE/Re/Wm

Page 17

Date 03/2003

Mechanical watches and electric data carriers as well
as digital watches or pocket calculators :

150 mm distance.

Data carriers such as credit cards, cheque cards, ID
cards with magnetic strips or magnetic tapes :

150 mm distance.


7.5.3 Changing the radial ball bearings

When changing the radial ball bearings, you merely
need to remove the bearing pedestal from the plant.
For removal and dismantling of the bearing pedestal,
see Sections 7.6.1 and 7.6.2.

7.6 Dismantling

There are three possibilities for dismantling:
1. Dismantling the entire pump from the plant.
2. Dismantling the entire slide-in unit, i.e. the housing

remains in the plant.

3. Removing only the drive section, i.e. the pump

does not need to be drained (back-pull-out design).
See Section 5.8.

Dismantling of the entire pump is described.
¾

Secure pump on a workbench or worktop with the

suction nozzle facing downwards.

¾

Screw ring bolt M 8 into the drive shaft.

7.6.1 Removing bearing pedestal

Caution! Magnetic forces!

Risk of accident!

Axial forces are produced when the bearing pedestal
is pulled out of the lantern. These forces diminish
again abruptly after it has been removed.
The operating torque of the magnetic coupling in-
stalled is specified on the type plate.
¾

Undo bearing pedestal screwing 901/1, 554/4.

¾

Detach the bearing pedestal from the lantern cen-

tering, if necessary using 2 levers.

If required you have the possibility to use the two
threaded holes in the beating frame for jacking
screws.

Group 1

- M 12

Group 2

- M 14

¾

Raise the bearing pedestal unit off the lantern with

a crane or pull it by hand out of the lantern.

¾

Remove flat gasket 400/1.

7.6.2 Dismantling bearing pedestal

¾

Clamp drive shaft 213 with its end in the vice.

¾

Undo hex. socket screw 914/1 in counterclockwise

direction.

¾

Pull off drive magnet assembly 858.

¾

Remove pump from the vice.

¾

Undo rear bearing cover 361.

¾

Remove wavy spring washer 953/1.

¾

Pull out drive shaft 213 with both ball bearings 321.

¾

Both radial ball bearings lie against the shaft collar

so remove singly on a press.

¾

Remove support bracket 183.


7.6.3 Removing lantern, can and plain

bearing pedestal

¾

Undo housing screwing 901/3, 554/3.

¾

Do not undo the two screws 901/5 (if installed).

They hold the lantern 344, can 159 and plain bear-
ing pedestal 339 together.

¾

Pull the entire slide-in unit out of the housing 100.

¾

If the housing does not move (e.g. owing to corro-

sion at the centering), remove the two plastic plugs
from the lantern 344.

¾

Screw in jacking screws M8 and use them to press
off the lantern.


7.6.4 Dismantling lantern, can and plain

bearing pedestal

¾

Place the unit lantern 344 / plain bearing pedestal

339 / impeller 230 on the workbench with the im-
peller facing upwards.

¾

Remove the two hex. screws 901/5 or the 3 set-

screws 904/2 (depending on size).

¾

Remove lantern 344 and can 159.

¾

Place remaining unit on the inner magnet assem-

bly.

¾

Place strap wrench around the impeller and undo

the impeller nut 231 counterclockwise.

¾

Pull off impeller 230.

¾

Remove key 940/2, distance washer 551/1 and

intermediate ring 509/2.

¾

Pull the plain bearing cartridge 310 with plain bear-

ing pedestal 339 out of the inner magnet assembly
859.

¾

Remove 2

nd

intermediate ring 509/1 from the inner

magnet assembly 859.

¾

Undo screws 901/1 and remove plain bearing car-
tridge 310 from the plain bearing pedestal 339

.