General information, General, Pump description – Goulds Pumps VRS - IOM User Manual

Page 15

Advertising
background image

GENERAL INFORMATION

GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
PUMP DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
NAMEPLATE INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
RECEIVING THE PUMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Storage Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Handling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

GENERAL

Keep this instruction manual handy for reference. Further
information can be obtained by contacting Goulds Pumps,
Ashland Operations, 500 East Centre St., Ashland, PA
17921 or your local representative.

Goulds Pumps will not be liable for any damages or delay
caused by failure to comply with the provisions of this
instruction manual. This pump is not to be operated at

speeds, working pressures, discharge pressures, or
temperatures, nor used on liquids other than stated in the
original order acknowledgment without written permission
of Goulds Pumps.

PUMP DESCRIPTION

The Model VRS pump is a rubber lined vertical cantilever
centrifugal pump. The wet end of the pump contains the
same casing halves, liners, and impeller as a similar size
Model SRL pump.

The impeller is threaded onto the shaft. It is axially
adjustable by means of jacking bolts in the thrust housing
to renew and maintain proper leakage path clearances.

The heavy duty bearing frame is made of cast iron and
contains a deep groove ball bearing on the inboard side and
an angular contact ball bearing on the outboard side. All
bearings are grease lubricated through fittings on the
bearing frame. The direction of rotation is clockwise when
viewed from the power end to the wet end.