Warning, Nstallation, Ttention – Glastender MFV48 User Manual

Page 7: Nstaller

Advertising
background image

6

Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780

800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com

a

ttention

i

nStaller

: WARNING!!

Failure to level this cooler WILL VOID THE FACTORY WARRANTY. Doors will not close properly causing

damage to hinges, handles, and/or gaskets which will adversely affect the refrigeration systems.

COOLER WITH 6" LEGS

COOLER WITHOUT LEGS

Cleaning Instructions continued from page 5
NOTES:

1. Never use hydrochloric acid, wire brushes, steel wool, scrapers, or chlorine based cleaners on stainless steel surfaces,

since they will break down the passivity layer and allow corrosion to occur.

2. On stainless steel surfaces, you may use a soft bristle brush or Scotch-Brite® pad for more stubborn stains. Always

scrub with the direction of the grain. Follow with a thorough cleaning as described above.

3. Deposits from food preparation must be properly removed. Even hard water deposits will rust stainless steel, if not

removed.

4. Repeated cleaning may dry up black-vinyl-clad steel (exterior) surfaces of the cooler. Armor All® or similar product

can bring back the shine. Apply the product to a cloth and then rub into the surface, rather than spraying it directly onto

the black-vinyl-clad surface.

5. The cooler door gaskets are most often overlooked when cleaning. Failure to clean them regularly will lead to prema-

ture failure, since alcohol and moisture build-up breaks down the gasket material.

6. Take care when removing the front grill to clean the compressor compartment as the thermostat control probe wire

connector may become disconnected. See page 2 for complete information.

S

ealing

V

ertiCal

d

oor

C

ooler

to

F

loor

To comply with NSF & health codes if the unit is not on legs or casters, the cooler base must be sealed to the floor using

NSF listed sealant. Place a bead of sealant along outer edges of the base and remove excess with disposable towel. The

floor sealing procedure does not apply to models that include legs or casters.

i

nStallation

Side View of Cabinet

COOLER

DOOR

COOLER CABINET

1" BASE

BEAD SEALANT

FLOOR

MAGNETIC GASKET

Advertising
This manual is related to the following products: