1

Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780

800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com

I

nstallatIon

I

ntroductIon

This manual describes the operational features of the Reach-In Mug Chiller model MFV24. Please review this information

before attempting installation and operation.

Long term, trouble-free service will follow if good housekeeping and maintenance procedures are followed. Thank you for

selecting Glastender, Inc. products.

u

tIlIty

r

equIrements

and

c

onnectIons

Electrical: 115 Volt AC, 1 Phase, 60 Hz, 8.55 Full Load Amps. A separate 15 Amp circuit is recommended. A 6-foot

grounded cord is included.

Plumbing: Automatic condensate evaporator is included. No drain connection required.

u

ncratIng

and

s

tart

-u

P

I

nstructIons

All Reach-In Mug Chiller models are shipped in one carton. These steps should be followed:

1. If legs or casters are included, bolt them to the base with the bolts provided.

2. Unwrap power cord from base.

3. Position the Reach-In Mug Chiller and level and/or seal as required (see page 2).

4. Install shelves.

5. Plug into 115 volt AC outlet.

6. Load with mugs, glasses, plates, etc.

7. Your Glastender Reach-In Mug Chiller is now ready for use.

o

PeratIon

The Reach-In Mug Chiller is designed to chill mugs, glasses, plates, etc. that will appear “frosted” when removed. The operating

temperature range of 0°F(-18°C) to 35°F(2°C).

The Reach-In Mug Chiller should be filled with dry, room-temperature mugs, glasses, plates, etc. to allow maximum chilling.

During business hours, the Reach-In Mug Chiller can be loaded with additional dry, room-temperature mugs, glasses, plates,

etc. Allow 30 minutes for chilling.

The Reach-In Mug Chiller includes an automatic defrost system. Defrosting will occur every six hours for approximately 20

minutes. During the defrost cycle, the fan inside the Reach-In Mug Chiller will turn off and a small amount of mist may appear

if the door is opened.

There is also a manual defrost system controlled by a switch located on the front left bottom of the Reach-In Mug Chiller. This

is used when there is ice or snow accumulation inside. An end-of-the-day or weekly schedule can be established for the activa-

tion of this manual defrost cycle.

When the manual defrost switch is pushed, a light will turn on and the Reach-In Mug Chiller will go into a six-hour defrost.

After six hours, the Reach-In Mug Chiller will resume normal operation.

If the manual defrost switch is accidentally pushed, the defrost cycle can be terminated by unplugging the power cord for

three seconds.