Nstallation – Glastender MFV24 Reach-In Mug Chillers User Manual

Page 5

Advertising
background image

e

lectrIcal

and

r

efrIgeratIon

s

PecIfIcatIons

c

leanIng

I

nstructIons

Cleaning is essential to sustaining the integrity of your equipment and preventing corrosion.
ESTIMATED CLEANING TIME: 5 to 10 minutes per unit daily, 45 minutes quarterly
FREQUENCY: Daily cleaning of exterior & door gaskets. Quarterly cleaning of interior, including shelves.
PROCEDURE:

1. A non-chlorine based cleaner or mild detergent and warm water applied with a soft cloth or sponge to all contact surfaces.

2. Immediately rinse off cleaning agent(s), using clean warm water, clean soft cloth or sponge.

3. Dry with a soft clean cloth, removing standing water as soon as possible.
NOTES:

1. Never use hydrochloric acid, wire brushes, steel wool, scrapers, or chlorine based cleaners on stainless steel surfaces,

since they will break down the passivity layer and allow corrosion to occur.

2. On stainless steel surfaces, you may use a soft bristle brush or Scotch-Brite® pad for more stubborn stains. Always

scrub with the direction of the grain. Follow with a thorough cleaning as described above.

3. Deposits from food preparation must be properly removed. Even hard water deposits will rust stainless steel, if

not removed.

4. Repeated cleaning may dry up black-vinyl-clad steel (exterior) surfaces of the cooler. Armor All® or similar product

can bring back the shine. Apply the product to a cloth and then rub into the surface, rather than spraying it directly onto

the black-vinyl-clad surface.

5. The cooler door gaskets are most often overlooked when cleaning. Failure to clean them regularly will lead to prema-

ture failure, since alcohol and moisture build-up breaks down the gasket material.

s

ealIng

r

each

-I

n

m

ug

c

hIller

B

ase

to

f

loor

To comply with NSF & health codes. The Reach-In Mug Chiller base must be sealed to the floor using NSF listed sealant.

Place a bead of sealant along outer edges of the base and remove excess with disposable towel.

2

Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780

800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com

I

nstallatIon

d

esIgn

m

odel

r

efrIgerant

P

ressure

(L-to-R

length

)

e

lectrIcal

t

yPe

c

harge

h

Igh

l

oW

24”

115V, 1Ph., 60 Hz., 8.55 Amp

R404A 9.75oz.

350

175

Advertising