Emperature, Ontrol – Glastender BLC-3/4-2 User Manual

Page 6

Advertising
background image

5

Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780

800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com

8. e

LeCtRoniC

t

empeRatuRe

C

ontRoL

p

RoGRamminG

BLC-1/3, BLC-1/3-2, BLC-1/2, BLC-1/2-2, BLC-3/4, BLC-3/4-2 (note: t

his

ContRoL

useD

on

units

pRioR

to

11/21/2013 sn134147623x):

The unit is shipped from the factory set at 26°F, differential set at 5, in C1, cooling mode. If reprogramming or adjust-

ing is necessary follow these steps:

Step 1 Press the SET key to start programming.

Use the up or down arrow to toggle between and select F for degrees Fahrenheit or C for degrees Celsius.

Step 2 Press the SET key again to access the setpoint.

To achieve the desired temperature, press the UP key to increase or the DOWN key to decrease the setpoint.

Step 3 Press the SET key again to access the differential.

To achieve the desired differential, press the UP key to increase or the DOWN key to decrease the setting.

Step 4 Press the SET key again to access the mode.

Use the up or down arrow to toggle between and select C1, cooling or H1, heating mode.

Step 5 Press the SET key again to complete programming.

C

oLD

C

ontRoL

a

Djustment

, BLC-1/3-e

The unit is shipped from the factory set at 26°F, differential set at 5. To decrease the temperature turn the adjusting knob

clockwise. To increase the temperature turn the adjusting knob counter clockwise.

t

empeRatuRe

C

ontRoL

Scale

Adjusting Knob

Advertising
This manual is related to the following products: