Glastender Bottle Disintegration System User Manual

Page 7

Advertising
background image

6

Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780

800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com

Odor Control Cleaning:
Use one or a combination of the following steps as needed to control odor.

A. Introduce a multipurpose, water-soluble, malodor counteractant, such as Disappear® by Franklin Mainte-

nance Products. Note: NEVER use chlorine.

1. Pour a few drops of malodor counteractant down the chute opening or pour some in a bottle prior to

crushing.

B. Clean interior surfaces:

1. Turn off unit. Wait 60 seconds before opening door.
2. Open door, remove bucket, and empty cullet.
3. Rinse out bucket with hot, soapy water.
4. Vacuum out interior of bottom enclosure.
5. Clean interior of unit per General Cleaning and Care Instructions for Stainless Steel, page 5.
6. Replace bucket and shut door.

C. Clean bottle chute (NOTE: Reference page 8 for bottle chute assembly diagram):

1. Unplug unit.
2. Remove Top Cover by removing eight (8) screws and lifting off the top cover.
3. To clean the bottle chute:

a. Disconnect the safety switch.
b. Remove the eight (8) screws and nuts (4 each) for Top Cover of Bottle Chute to Small Tube Weldment

and for Small Tube Weldment to Large Tube Weldment.

c. Remove the rubber and plastic gaskets and wash with warm, soapy water.
d. CAUTION: Do NOT get electrical components wet! Clean per General Cleaning and Care Instructions

for Stainless Steel, page 5.

e. Re-assemble bottle chute. Note: The middle plastic gasket must be oriented with the star pattern offset

of the star pattern of the rubber gasket.

f. Re-connect safety switch.

4. Replace top cover and re-install eight (8) screws.
5. Plug in unit.

c

leaning

i

nstructions

Advertising