Table 3-3. dsl line unit status conditions -6, List – ADC EMU-830 User Manual

Page 38

Advertising
background image

Chapter 3: Provisioning

September 25, 2006

3-6

LTPE-UM-3159-02

Table 3-3. DSL Line Unit Status Conditions

Table 3-4. DSL Circuit Alarms in Order of Severity

State

Indicator

Description

Normal

–

The circuit has no active alarms. This can be because one or more of the
circuit's alarms are disabled from being reported at the DSL card.

Not Occupied

/

No unit is installed in the slot, or the unit is not recognized.

Alarms Disabled D

Alarm reporting has been disabled for this circuit at the EMU-830. This can be
changed using selection 2 from the Main menu.

Not Manageable X

The DSL card in the slot does not support centralized management by the
EMU-830.

NTU/STU-R

N

The DSL card in the slot is an NTU/STU-R card. Alarms for a circuit with an
NTU/STU-R card residing in the managed shelf are not reported on this screen.
You can, however, login to the NTU/STU-R card using selection 1 from the Main
menu to view the alarm status.

Both loops

*

The indicated alarm involves both loops.

Alarm

Alarm
abbreviation

The most severe active alarm in the circuit is shown.

Priority

Name

Description

Card Type

1

PFO

PFO1
PFO2

Power feed open on both loops
Power feed open on loop 1
Power feed open on loop 2

HDSL

2

PFS

PFS1
PFS2

Power feed short on both loops
Power feed short on loop 1
Power feed short on loop 2

HDSL

3

LOSW

LOSW1
LOSW2

Loss Of Synch Word on both loops
Loss Of Synch Word on loop 1
Loss Of Synch Word on loop 2

HDSL

G.SHDSL

4

LOS

Loss of Signal on any G.703 interface

HDSL

G.SHDSL

5

LOC

Loss of clock (sourced from External
clock, or Nx64K data port)

HDSL

UTU-91X

5

LEC
LDC

Loss of External clock alarm
Loss of Nx64K data port clock alarm

WD92xGx

6

MAL

MAL1
MAL2

Below margin threshold both loops
Below margin threshold on loop 1
Below margin threshold on loop 2

HDSL

G.SHDSL

7

LAL

LAL1
LAL2

Loop Attenuation alarm both loops
Loop Attenuation alarm loop 1
Loop Attenuation alarm loop 2

HDSL

G.SHDSL

8

ESAL

ESAL1
ESAL2

Errored Second alarm both loops
Errored Second alarm on loop 1
Errored Second alarm on loop 2

HDSL

G.SHDSL

Advertising