7

Heat Controller, Inc.

VMH 30/36 SERIES

Owner’s Manual

Adjust the air flow direction properly otherwise, it

might cause discomfort or uneven room

temperatures.

Adjust the horizontal louver using the remote

controller.

Adjust the vertical louver manually.

To set the vertical air flow(Up--Down) direction

Perform this function while the unit is in operation.

Use the remote controller to adjust the air flow

direction. The horizontal louver can be moved at

O

a range of 6 for each press, or swing up and down

automatically depending on model. Please refer to the

REMOTE CONTROLLER OPERATION MANUAL that

come with your unit for details.

NOTE: This manual does not include Remote Controller Operations, see the

Remote Controller Instruction manual packed with the unit for details.

Operating conditions

Mode

Temperature

Room temperature

Outdoor temperature

1. Optimum performance will be achieved within these operating temperatures.

2

. If the air conditioner operates in excess of 80% relative humidity, the surface of the air

conditioner may attract condensation. Please set the vertical air flow louver to its

maximum open angle (vertically to the floor), and set the fan to HIGH mode.

O

32 F(

. If air conditioner is used outside of the above conditions, certain safety protection

features may come into operation and cause the unit to function abnormally.

3

Suggestion: For units with crankcase heaters when the outside ambient

O

temperature is below

0 C), we strongly recommend you to keep the machine

plugged in order to guarantee it running smoothly.

CAUTION:

7

8

OPERATING INSTRUCTIONS

Airflow direction control

To set the horizontal air flow direction (left - right)

Move the vertical louver manually to adjust the air flow

in the direction you prefer.

IMPORTANT: Before adjusting the vertical louvers, the

supply power must be disconnected to prevent electrical

shock or injury.

For some models, the vertical louver can be adjusted

by using the remote controller. Please refer to the

REMOTE CONTROLLER OPERATION MANUAL

that comes with your unit for details.

Do not operate the air conditioner for long periods with

the air flow direction set downward in cooling or

dehumidifying mode. Otherwise, condensation may

occur on the surface of the horizontal louver causing

moisture to drop on to the floor or on furnishings.

Do not move the horizontal louver manually unless it is

necessary. Always use the remote controller, where

applicable.

When the air conditioner is started immediately after it

was stopped, the horizontal louver might not move for

approximately 10 seconds.

Open angle of the horizontal louver should not be set

too small, as COOLING or HEATING performance may

be impaired due to too restricted air flow area.

Do not operate unit with horizontal louver in closed

position.

When the air conditioner is connected to power (initial

power), the horizontal louver motor may generate a

sound for 10 seconds, this is a normal occurance.

CAUTION

Manual operation can be used temporarily in case the remote controller is disabled or

when maintenance is necessary.

OPERATING INSTRUCTIONS

Manual operation

Manual control

button

Front panel

AUTO/COOL

Range

Range

Vertical

louver

(three places)

Open and lift the front panel up to an angle

until it remains fixed with a clicking sound.

One press of the manual control button will

lead to forced AUTO operation. If press

the button twice within five seconds, the unit

will operate under forced COOL operation.

Close the panel firmly to its original

position.

This button is used for testing purposes only.

To restore the remote controller operation,

use the remote controller directly to operate

the unit. This will override the manual

operation.

CAUTION:

1

3

2

NOTE: The unit must be turned off before

using the manual control button. If the

unit is operational, continue pressing the

manual control button until the unit is off.

Heating

Operation

O

O

88 F(30 C)

O

O

5 F ~ 92 F

O

O

(-15 C ~ 34 C)

Drying

Operation

O

O

>50 F(10 C)

O

O

5 F ~ 122 F

O

O

(15 C ~ 50 C)

Cooling

Operation

O

O

62 F(17 C)

O

O

O

O

5 F~122 F (-15 C~50 C)

For the models with low

ambient controls.

O

O

32 F ~ 122 F

O

O

(0 C ~ 50 C)

OPERATING INSTRUCTIONS

Advertising
This manual is related to the following products: