ELECTRICAL INSTALLATION
WARNING: To assure safe operation, installa-

tion must be done by a certified electrician and

must adhere to local, state and national electrical

codes.
Use a certified ground fault protection device for

wet environment installations.
1. Supply voltage must correspond to the voltage

indicated on unit’s rating plate.

2. The cord from each terminal box must be hard

wired and properly grounded.

WARNING: Each power supply circuit must be

provided with a means of disconnection, and the

disconnecting means must be grouped.

WALL-MOUNTED INSTALLATION
WARNING: Observe minimum clearances shown

in chart above.
1. Securely fasten the L-shaped brackets to the

mounting surface using both of the fixing holes in

the short part of the bracket. NOTE: Wall bolts are

not supplied: select an appropriate size to provide

adequate support for the weight of the unit and

taking into consideration any wind load conditions.

CAUTION: If there is any question about security

of bolts and fixings, contact a professional con-

tractor.
2. Mount the heater to the brackets with the terminal

box at the bottom of the heater.

3. Adjust the heater to the desired directional angle,

then fix in this position by tightening the fixing

bolts on the brackets at the rear of the heater.

CAUTION: Do not position the heater at an angle

greater than 50° or less than 30°.

INTRODUCTION

Heat Controller’s infrared heater produces radiant heat that warms people and objects

rather than the air surrounding them. The heater can be mounted on a wall or ceiling,

and adjustable brackets allow the heat to be directed where desired.

This heater is designed for outdoor commercial use only.

MINIMUM CLEARANCE DISTANCES FROM...

MODEL

FLOOR

CEILING

ADJACENT

WALLS

IR30S

8' (2.44 m)

1' 8" (.51 m)

36" (.91 m)

IR60S

10' (3.05 m) 1' 8" (.51 m) 48" (1.22 m)

Installation & Operation

Radiant Infrared Heater

Heat Controller

4. Secure the electrical supply cable so it does not

come in contact with the heater body or obstruct the

air vents. Follow local and national electrical code

requirements.

CEILING-MOUNTED INSTALLATION
WARNING: Observe minimum clearances shown

in chart at left.
1. Heater should be hung using non-flexible mount-

ing brackets (not supplied). Select brackets that

will maintain a minimum clearance of 1' 8" (.51 m)

from the ceiling.

2. Bolts and fixings (not supplied) should be of an ap-

propriate size to provide adequate support for the

weight of the unit and any additional load resulting

from wind conditions.

CAUTION: If there is any question about security

of bolts and fixings, contact a professional con-

tractor.
3. Secure the heater to the mounting brackets with

the heater facing directly down.

4. Secure the electrical supply cable so it does not

come in contact with the heater body or obstruct

the air vents. Follow local NEC code require-

ments.

ADJUSTING DIRECTIONAL POSITIONING
WARNING! Never attempt to move heater while it

is operating. Personal injury could result.
1. Power to the heater from the main supply must be

OFF to adjust the position. (Turn off circuit breaker.)

2. Allow the heater to cool before re-positioning the

angle.

3. Loosen the fixing bolts on the brackets at the rear

of the heater; re-position heater as desired, then

re-tighten the fixing bolts.

CAUTION: Do not position the heater at an angle

greater than 50° or less than 30°.

3