IMPORTANT: Read through the emitter replacement

procedure below before beginning the replacement.
CAUTION: Do not touch emitter with bare hands.

Wearing soft cotton gloves is highly recommended.
1. Turn OFF power switch and disconnect from main

power supply (circuit breaker).

2. Be sure the heater and emitter are cool: burns can

result from touching hot components.

3. Remove the screws from the end of the heater

fixture and remove the aluminum end cap.

4. Carefully slide the perforated front grille immedi-

ately adjacent to the end cap off the end of the unit.

5. Carefully slide the protective grille to the end of

the heater to expose the emitter and silicone seal-

ing connectors.

6. Carefully remove the emitter and silicone wire

connectors from the aluminum emitter clips, free-

ing the wire/connector system.

7. Carefully remove the silicone terminal connec-

tors from the ends of the emitter. Be careful not to

break the emitter terminal end inside the silicone

wire connector. Discard the used emitter.

8. Holding the new emitter by the ceramic ends OR

wearing clean dry gloves, place the silicone termi-

nal connectors onto the new emitter and re-clip it

into the emitter holder.

9. Carefully slide the protective grille and perforated

end cap into place, and replace screws.

MAINTENANCE
There are only two maintenance procedures which

can be done on location: cleaning the unit and

replacing the emitter. Return the heater to an au-

thorized service faciity for any other electrical or

mechanical adjustment or repair, including replace-

ment of a damaged power cord.
Should the heater be dropped or damaged, or mal-

function at any time, immediately turn off the main

power source and do not use heater until it has been

examined by an authorized service facility.
CLEANING
To remove dust or dirt on the reflector, follow these

steps:
1. Turn the power switch OFF and disconnect heater

from the main power supply.

2. Remove the wire guard and carefully wipe the

reflector with a soft, lint-free cloth.

CAUTION: Do not touch the emitter. Finger marks

will burn into the quartz emitter during use and

cause premature heater failture.
If emitter is inadvertently touched, or if it needs to be

cleaned, carefully wipe it using rubbing alcohol or

methylated spirits.

REPLACING EMITTER
Contact your distributor for the correct replacement

emitter, providing the model number and rating from

the rating label. Not using an exact replacement

emiitter can cause the heater to fail.

Installation & Operation

Radiant Infrared Heater

Heat Controller

:HOOZRUWK$YH-DFNVRQ0,‡3K‡ZZZKHDWFRQWUROOHUFRP





Due to ongoing product improvements, specifications and dimensions

are subject to change and correction without notice and without

incurring obligations. Determining the application and suitability

for use of any product is the responsibility of the installer. Addition-

ally, the installer is responsible for verifying dimensional data on

the actual product prior to beginning any installation preparations.

Incentive and rebate programs have precise requirements as to

product performance and certification. All products meet applica-

ble regulations in effect on date of manufacture; however, certifi-

cations are not necessarily granted for the life of a product. There-

fore, it is the responsibility of the applicant to determine whether a

specific model qualifies for these incentive/rebate programs.

4

Advertising
This manual is related to the following products: