GB

Problem

Possible Cause

Solution

Tool operating slowly

Pressure incorrect

Set the correct air pressure according to the specification

Dirt within the mechanism

Pour oil into air inlet as per maintenance instructions

Air blockage

Operate tool in short bursts to clear blockage

Air leak

Check all fittings and hose for air leaks and correct issue by

re-tightening, using PTFE tape or replacing

Blockage in gauze mesh filter

Remove Quick Connector and clean mesh filter

Tool seized

Dirt or rust in mechanism

Try ‘Tool operating slowly’ solutions

Dirt or rust in mechanism

Tap tool gently with a soft mallet

Dirt or rust in mechanism

Free mechanism by rotating drive manually when disconnected

from air line

Tool will not stop after trigger

is fully released

Throttle valve O-ring or valve seat damaged

Have the tool repaired at an authorised Silverline service centre

If the above troubleshooting solutions fail, contact your dealer or an authorised Silverline service centre.