Operating instructions, Troubleshooting, Maintenance – Silverline In-Car Inverter 160W User Manual

Page 7: Disposal, Problem possible cause suggested remedy

Advertising
background image

6

GB

Operating Instructions

Connecting a mains device

• Do not connect loads greater than the rated maximum continuous power

output of the inverter (see specifications)

• If the appliance to be connected does not have a wattage (W) indication,

the wattage can be calculated by multiplying the amperage (A) by 230

• Some devices may require a much higher starting current than their

rated average power consumption. This inverter is designed to allow for
such inductive devices that have high current demands on first switch
on. If a device will not start at all it is likely it has exceeded this capacity
and is not compatible with the inverter

• The inverter features a 230V Universal Mains Socket (2) compatible with

UK, European, American and Australian plugs. It will also be compatible
with other countries and regions which adopt these standards for plugs.
It is important to note the inverter must only be used with devices
compatible with 230V AC 50Hz and if you are using a non-UK device with
this inverter, you must check its voltage and frequency are compatible

Warning: Any device fitted with a American 2-pin plug must be checked to
make sure it is compatible with 230V 50Hz AC, as most are only compatible
with 120V 60Hz AC. If you have any doubt about its compatibility DO NOT
USE
Warning: At 160W the inverter will draw 12-15A at 12V, so a typical, fully
charged vehicle battery of 80Ah will last 5-6hrs. If you use the inverter
without the vehicle’s engine operating, you may discharge the battery
and prevent the vehicle from starting. Ideally the inverter should only be
used when the engine is running unless you limit how long you use the
inverter off the vehicle’s battery. It is recommended that the vehicle engine
should be started and run once every hour to 'top up' the battery using the
vehicle’s alternator, allowing 10-15 minutes approximately for every hour
of use at full capacity. For a more precise figure consult the manufacturer
of your vehicle. To start a vehicle the battery must be in a high charge state.
Using the inverter incorrectly will prevent your vehicle from starting.
Notes:
• The inverter may shut down as the engine is started due to the high

electrical load generated by the vehicle starter motor

• This inverter is equipped with a low voltage alarm and automatic low

battery shutdown. If the supply voltage drops to 10.5V the low battery
alarm will sound. This indicates that the battery is in a discharged state
and requires charging. If the supply voltage is allowed to drop to 10V,
the inverter will automatically cut out. To restart the inverter, switch off,
charge the vehicle battery, and switch back on

Troubleshooting

Problem

Possible cause

Suggested remedy

Inverter will not operate

Low battery voltage


Inverter in thermal shutdown


12V connector not properly inserted


Internal fuse 'blown'

Charge or replace battery


Allow inverter to cool before switching on


Check connector is secure and use tension switch if required


Replace fuse

Electrical appliance will not

operate

Starting load of appliance is too great

Device not compatible

Low voltage alarm on

continuously

Poor electrical connections


Inadequate power supply

Check/clean electrical connections


Check 12V system capacity and battery condition

Low output voltage

Inverter is overloaded


Input voltage is below 11V

Reduce load


Charge or replace battery

Television/stereo interference

Inverter is located too close to aerial


Aerial cable is not shielded

Move inverter/aerial


Use shielded cable

• This inverter uses modified sine wave output which simulates AC voltage.

Although compatible with most devices, some may not be compatible. If
the product makes abnormal noises or functions differently to normal, do
not use with this inverter

• The AC output of an inverter cannot be accurately measured with

a normal multi-meter. The multi-meter will read 20-30V less than
expected. This does not indicate a fault with the unit

Connecting a USB device

The inverter has a built in USB Socket (3) for powering or recharging USB
devices. Please note the maximum current in the specification which should
not be exceeded.

Maintenance

Fuse Replacement

To replace the fuse of the inverter unscrew the Cigarette Plug Positive
Connector (5) and remove the fuse. Only replace with a fuse of exactly the
same rating as fitted.

Cleaning

• Disconnect the inverter from the power supply before cleaning
• Keep your inverter clean. Always clean dust or particles away and never

allow ventilation holes to become blocked. Use a soft brush, or dry cloth
to clean the inverter, if possible blow through the ventilation holes with
clean, dry, compressed air

Disposal

• Do not dispose of power tools, or other waste electrical and electronic

equipment, with household waste

• Contact your local waste disposal authority for information on the correct

way to dispose of tools

675258_Z1MANPRO1.indd 6

19/02/2013 09:47

Advertising