Multi-Stage
Centrifugal
MVP Pumps

Operations and Maintenance
Instructions

WARNINGS/CAUTIONS
Read all these SAFETY INSTRUCTIONS BEFORE
installing or using this equipment. Keep this
manual handy for reference/training.
ƒ Inspect unit for damage. Report any damage to

carrier/dealer immediately.

ƒ Pump may be heavy. If in doubt, take appropriate

precautions.

ƒ Motor must be grounded and suitable for the

environment in which it is used. Do not use where

explosion-proof motors are required.

ƒ Do not allow liquids to come into contact with the

motor, or any electrical components.

ƒ Never attempt any service work while the unit is

still connected to any electrical power source.

ƒ This pump contains rotating parts. Use caution.
ƒ When working on or around pump, be aware of

what liquid is/has been pumped. If liquid is
potentially harmful, take appropriate precautions.

ƒ Never use any part of the wiring/electrical system

to lift or move the equipment. This could cause a
failure of the electrical system, resulting in severe
shock or death.

ƒ Do not operate this pump or allow others to

operate it until the instructions and warnings have
been read and are understood by all involved.

Never work with equipment you feel may be unsafe.
Contact your Supervisor immediately.

DESCRIPTION/SPECIFICATIONS

The Graymills MVP Series pumps are multi-stage
centrifugal pumps designed to handle clean, water and
water-based coolants.

ƒ Minimum and maximum liquid temperature range: -

10

0

C to 93

0

C(50

0

F to 200

0

)

ƒ Maximum Air Temperature 40

0

C (104

0

F)

ƒ Maximum viscosity 500 SSU
ƒ Maximum On/Off Cycles per hour: 100
ƒ Maximum inlet pressure 100 psi.
ƒ Pipe connections are 1" NPT for both inlet and

discharge.

ƒ Bypass kit is included and should be used for

applications where low flow conditions can exist.
See Installation Section, Page 2.

ƒ Rotation: left hand, ie, COUNTERCLOCKWISE

when viewed from motor end.

POWER SUPPLY, WIRING AND
GROUNDING

WARNING

Install ground and wiring according to local and
National Electrical Code requirements.
ƒ Install a disconnect switch on all power legs near

the pump.

ƒ Disconnect and lockout electrical supply before

installing or servicing pump.

ƒ 230/460V, 3 phase, 60 cycle AC circuit rated for a

minimum of 10 amps. Refer to motor nameplate for
instructions.