795-92645 03-13 Bed Filter/Magnetic Separator OMI

10 Turn on system and monitor operation to make sure all

connections are tight and fluid circulation is functioning.

Watch as the coolant drains from the machine tool back into

the collection tank. Make sure that it is flowing freely. Check

rotation of pump. Rotation should be in a clockwise direction

looking down on the motor (match arrow on pump body).

11 Make any final adjustments to float switch to ensure level of

liquid in filter bed does not exceed height of chain on either

side. To adjust the liquid level, turn the screw on the floating

ball switch. To lower the level, turn clockwise. To raise the

level, turn counter-clockwise.

OPTIONAL MAGNETIC SEPARATOR
With Bed Filter

1 Verify operating voltage and make any necessary changes

to the connections located on the underside of the Magnetic

Separator—the unit is a dual voltage system and the default

setting should be 230V, 3Ph. Follow the wiring schematic

(Figure 3) to check/change the power settings. All electrical

connections should conform to national/local codes and be

made by qualified personnel.

2 Remove solid cover plate from end of bed filter to expose

frame rails.

3 Position the Magnetic Separator as shown in Figure 1. Make

sure mounting feet are resting on the metal supports of the

bed filter and the mounting holes are centered on those

supports. The discharge chute should be pointing into the

Sludge Box.

4 Use self tapping screws to fasten the Magnetic Separator to

the support rails.

5 Plumb the outlet of the Magnetic Separator so that the flow is

routed back into the center of the diffuser tray where it can

be run through the filter media. Plug the outlet port that is not

being used with the fitting provided.

6 Visually inspect scraper blade so it is just lightly touching the

surface of the magnetic roller.

7 Complete the electrical connections and make final

adjustments.

Without Bed Filter

1 Verify operating voltage and make any necessary changes

to the connections located on the underside of the Magnetic

Separator - the unit is a dual voltage system and the default

setting should be 230V, 3Ph. Follow the wiring schematic

(Figure 3) to check/ change the power settings. All electrical

work must be according to applicable codes.

2 Remove the intake trough and plumbing from the small tank lid.
3 Positioning the Magnetic Separator on the tank is not critical

and optimal location is at the discretion of the operator.

We recommend that the discharge chute hangs over the

side of the tank directing refuse directly into the plastic tray

provided with the magnetic separator.

4 Use self tapping screws to fasten the Magnetic Separator to

the tank lid.

5 Plumb the outlet of the Magnetic Separator so that the flow

is routed back into the tank. Plug the outlet port that is not

being used with the fitting provided.

6 Complete the electrical connections and make final

adjustments to suit your application.

MAINTENANCE

Be sure power to the unit is shut off before performing

maintenance on your machinery.
• For continued service, have an extra roll of filter media

available.

• Replace the used filter media before you reach the end of

the roll to avoid letting the uncleaned coolant flow directly

into the tank.

• If necessary, remove bottom cap and impeller, clean volute

cavity to remove obstructions. Replace impeller and bottom

cap.

• Check and clean the diffuser tray (D, page 2) frequently to

keep coolant flowing into the bed filter.

• Be sure to dispose of the drained sludge from the sludge

collection box before it is full.

• Dispose of used media according to all federal, state and

local regulations.

• If you are using a Magnetic Separator, check it frequently

and dispose of metal debris. Check the scraper to be sure

it is cleaning the roller. Scraper should make only light

contact with the surface of the roller. Use wing nuts to make

adjustments, loosening to decrease pressure on the scraper.

Clean sludge from the scraper and roller so that it does not

harden and cause a malfunction. Clean away metal chips as

necessary.

• If the Magnetic Separator will not be used for an extended

period of time, loosen the wing nuts to decrease pressure of

the scraper on the roller. This will extend roller life.

• Empty and clean the unit as necessary. Check the diffuser

tray, chain and tank. Wipe out all debris with a rag.

• To prolong finish quality, wipe off the exterior of the

machinery with a clean, damp cloth as needed.

W

2

U

2

V

2

U

1

V

1

W

1

230V

RED

BLUE

BROWN

BLACK

YELLOW

WHITE

W

2

U

2

V

2

U

1

V

1

W

1

460V

W

2

U

2

V

2

U

1

V

1

W

1

230V

RED

BLUE

BROWN

BLACK

YELLOW

WHITE

W

2

U

2

V

2

U

1

V

1

W

1

460V

Figure 3

Wiring diagram for Magnetic

Separator (inside unit)

Figure 2 Wiring diagram for Bed Filter

BFTS40, 80, 120 BFTS160

Figure 4

Wiring diagram for full system