Installation Instructions

The default factory settings will be used in almost every application. They are:

Group 1

Terminator OFF

NOTE: If necessary, follow the procedure below to change the DIP switch settings before installing strike.

IMPORTANT: Ensure that the serial number of the unit is retained. Once the device is locked and
encryption enabled, access to the device requires the serial number. If the serial number is lost, the device
must be returned to the factory to be reset.

A.

B. SWITCH 1: Set the manual group switch. Default is OFF and is appropriate for most applications. Most

installations use Group 1 only.

Switch 1 OFF = membership in Group 1.

Switch 1 ON = membership in Group 2.

B. SWITCH 2: Set the termination resistor (Default is OFF). In a Hi-O CANbus network, it is necessary to

terminate the communication bus to avoid interference. Termination should take place in Activators, for
example in a card reader, opening button, or a gateway.

Switch 2 OFF removes the 120 ohm connection between CAN-Low and CAN-High.

Switch 2 ON terminates a 120 ohm resistor between CAN-Low and CAN-High.

Use only one termination resistor per application.

Refer to the Hi-O Systems Manual (A8002) for additional information.

Adjustment Instructions

DO NOT DAMAGE LABEL. This label
will be re-applied after DIP switch
setting is complete.

After label is removed, carefully use a
small screwdriver to set DIP switch (see
instructions 2 and 3).

When setting is complete, re-apply the
serial label to the back of the strike.

To change the settings, remove the label from the back of the strike.

Switch

position

default

settings

ON

1 2