5 locking the front panel buttons, 8 using the configuration menu, 1 using the setup menu – Kramer Electronics VS-6464DN User Manual

Page 26: Locking the front panel buttons, Using the configuration menu, Using the setup menu, On 7.5, On 8

Advertising
background image

KRAMER: SIMPLE CREATIVE TECHNOLOGY

Using the Configuration Menu

22

7.5 Locking the Front Panel Buttons

You can lock

1

To lock the front panel buttons:

the VS-6464DN to prevent tampering with the unit or

prevent the settings from being changed accidentally via the front panel

buttons.

•

Press and hold LOCK until the button lights.

The front panel buttons are locked

To unlock the front panel buttons:

•

Press and hold LOCK until the button is no longer lit.

The front panel buttons are unlocked

8 Using the Configuration Menu

The configuration menus let you configure the VS-6464DN to best suit your

needs. There are two configuration menus:

•

Setup Menu—those that are accessed on a regular basis (for example,

storing setups and setting the delay), see

Section 8.1

•

Config Menu—those that are accessed only occasionally (for

example, setting the interface or communication protocol), see

Section 8.2

The following rules apply to the menu operation:

•

If no selection is made within approximately 15 seconds, the

operation times-out and the display reverts to the output/input display

•

At any point in the Menu, press ESC to move up one level or press

BREAKAWAY to exit the Menu altogether

•

At any point in the Menu, only buttons that are active light or flash

•

All of the procedures in this section assume that you are starting the

procedure from the standard, operational output/input display

8.1 Using the Setup Menu

The Setup Menu provides access to settings that are regularly changed and

comprises the following options:

•

1: inXX=>ALL, switching one input to all outputs (see

Section

8.1.1

)

•

3: outXX=OFF, turning off an output (see

Section 8.1.2

)

•

7: EDID, assignment to an output (see

Section 8.1.3

)

•

9: Delay setting for an output (see

Section 8.1.4

)

•

4: store setup XX, storing the setup in a preset (see

Section 8.1.5

)

•

6: recall setup XX, recalling a preset (see

Section 8.1.6

)

1 You can still operate the device remotely via RS-232 or Ethernet when the front panel is locked

Advertising