8 technical specifications, 9 communication parameters, Technical specifications – Kramer Electronics VS-88HD User Manual

Page 28: Communication parameters, Table 6: vs-88hd technical specifications, Table 7: communication parameters, 8technical specifications, 9communication parameters

Advertising
background image

KRAMER: SIMPLE CREATIVE TECHNOLOGY

Technical Specifications

24

8

Technical Specifications

The VS-88HD technical specifications are shown in

Table 6

:

Table 6: VS-88HD Technical Specifications

1

INPUTS:

8 SMPTE-259M, 344M, 292M and 372M (dual link)

serial video, 75Ω on

BNC connectors

OUTPUTS:

8 equalized and reclocked SMPTE-259M, 344M, 292M and 372M (dual

link)

outputs 75Ω on BNC connectors

MAX. OUTPUT LEVEL:

800mVpp /

75Ω

DATA RATE:

1.485Gbps

EQUALIZATION:

Automatic equalization for losses on 75

Ω coaxial cable

CONTROLS:

Front-panel, RS-232, RS-485, ETHERNET, remote infrared

POWER SOURCE:

Universal, 100-240V AC, 50/60Hz 24VA

DIMENSIONS:

19" x 7" x 1U W, D, H, rack mountable

WEIGHT:

2.6kg (5.7lbs) approx.

ACCESSORIES:

Power cord, rack “ears” and IR remote control transmitter

OPTIONS:

External remote IR receiver cable

9

Communication Parameters

The following table lists the communication parameters for Protocol 2000
and Protocol 3000.

Table 7: Communication Parameters

EDID

EDID data is passed between Input 1 and Output 1

RS-232

Protocol 2000

Protocol 3000 (Default)

Baud Rate:

9600

Baud Rate:

115,200

Data Bits:

8

Data Bits:

8

Stop Bits:

1

Stop Bits:

1

Parity:

None

Parity:

None

Command Format:

HEX

Command Format:

ASCII

Example (Output 1 to Input 1): 0x01, 0x81, 0x81, 0x81

Example (Output 1 to Input 1):

#AV 1>1<CR>

Switching Protocol

P2000 -> P3000

P3000 -> P2000

Command:

0x38, 0x80, 0x83, 0x81

Command:

#P2000<CR>

Front Panel:

Press and hold Output 1 and Output
2 simultaneously

Front Panel:

Press and hold Output 1 and Output 3
simultaneously

Ethernet

Default Settings

Reset Settings

IP Address: 192.168.1.39

Power cycle the unit while holding in the Factory Reset button,
located on the rear panel of the unit.

TCP Port #: 5000

UDP Port #: 50000

1 Specifications are subject to change without notice