4 preset commands, 5 operation commands, 6 machine information commands – Kramer Electronics VS-88HD User Manual

Page 37: Preset commands, Operation commands, Machine information commands, Kramer protocol 3000

Advertising
background image

Kramer Protocol 3000

33

33

11.3.4 Preset Commands

Command

Syntax

Response

Store current connections to

preset

PRST-STO PRESET

Short form: PSTO PRESET

PRST-STO PRESET RESULT

Recall saved preset

PRST-RCL PRESET

Short form: PRCL PRESET

PRST-RCL PRESET RESULT

Delete saved preset

PRST-DEL PRESET

Short form: PDEL PRESET

PRST-DEL PRESET RESULT

Read video connections from

saved preset

PRST-VID? PRESET,OUT

Short form: PVID? PRESET,OUT

PRST-VID? PRESET, *

PRST-VID PRESET, IN>OUT

PRST-VID PRESET, IN>1, IN>2,…

Read saved presets list

PRST-LST?
Short form: PLST?

PRST-LST PRESET, PRESET, …

Parameter Description:

PRESET = Preset number.

OUT = Output in preset to display, '*' for all.


Examples:

Store current video connections

to preset 5

#PRST-STO 5CR

~PRST-STR 5 OKCRLF

Recall video connections from

preset 3

#PRCL 3CR

~PRST-RCL 3 OKCRLF

Show source of video output 2

from preset 3

#PRST-VID? 3,2CR

~PRST-VID 3: 4>2 CRLF

11.3.5 Operation Commands

Command

Syntax

Response

Lock front panel

LOCK-FP LOCK-MODE

Short form: LCK LOCK-MODE

LOCK-FP LOCK-MODE RESULT

Get front panel locking state

LOCK-FP?

LOCK-FP LOCK-MODE

Parameter Description:

LOCK-MODE = Front panel locking state:

‘0’ or ‘off’ to unlock front panel buttons
‘1’ or ‘on’ to lock front panel buttons

Reset device

RESET

RESET OK

Switch to protocol 2000*

P2000

P2000 OK

* Protocol 2000 has a command to switch back to ASCII protocol (like Protocol 3000)

11.3.6 Machine Information Commands

Command

Syntax

Response

Read in/out count

INFO-IO?

INFO-IO: IN INPUTS_COUNT, OUT

OUTPUTS_COUNT

Read max preset count

INFO-PRST?

INFO-PRST: VID PRESET_VIDEO_COUNT

Reset to factory default

configuration

FACTORY

FACTORY RESULT

Advertising