Networking one or more signs (shielded)

PWR

L2

DISPLAY

SERIAL COM

L1

(RS

232/485)

(RS

232)

WH

BL

BR

YL

GN

OR

BK

RD

SHLD

+ RS485 (Bla

ck)

– RS485 (Red)

NOTE: When signs are
networked to the
CPU Module, all
the signs must be
the same model
when ALPHA
Messaging software
is used.

1-foot RS485 cable or

8-foot RS485 cable

To next

sign

Maximum = 4ØØØ feet (@ 96ØØ baud)

•

Connect RED wire from RS485 cable to YL screw.

•

Connect BLACK wire from RS485 cable to BK screw.

•

ONLY connect SHIELD wire from RS485 cable to RD screw if the sign is a

Series 4ØØØ or Series 7ØØØ. For LEDarray, connect the two SHIELD wires
to each other, but

not to the RD screw.

RS485 cable

Connecting Using RS-485 Network

Enclosures

Use a twisted pair, 22awg with common shield.

Use modular adapter for network wiring.
Connect to sign with RJ-11 cable.

Mass Notification Signs

Connecting using RS-485 Network.

Modular Network

Adapter

FRONT VIEW

SIDE VIEW

Backbox

Door

4"

1 7/8"

12"

12"

MNS-CONTROLLER

28.9"

4.5"

SIGN IS 2.1” DEEP

DISPLAY AREA IS 27”L x 2.1”H

POWER

MASS NOTIFICATION SYSTEM

MODEL G1212

SYSTEM CONTACT / SIGN NETWORK INTERFACE

See Figure 1

Page 4

LEDARRAY DISPLAY

Rev. 1

Install EOL Device on last sign in network (supplied with controller).