3.

If the flue exits on back of stove and an

interior installation is desired (Figure 10):

A. Place the appliance according to the

manufacturer’s instructions.

B. Connect the Tee Adapter or combine Tee

with Cleanout and Pipe Adapter then seal and

secure the Pipe Adapter to the back of the

stove.

C. Continue to assemble Pipe Sections as

described in Step 2.

4.

If the flue exit is on the back of stove, and

an exterior vertical installation or partial vertical

installation is desired (Figure 11):

A. Place the appliance according to

manufacturer’s instructions.

B. Cut and frame a square opening in the wall

as specified in Table 1. PelletVent Pro can be

installed with the standard Wall Thimble, Wall

Thimble Air Intake Kit , or CAS Wall Thimble

for through the wall installations. If the CAS

Wall Thimble is used, refer to the PelletVent

Pro CAS Installation Instructions for direction

on how to install the Combustion Air System

(CAS). The Wall Thimble Air Intake Kit allows

combustion air to be drawn through the framed

Thimble opening, eliminating the need to

cut another opening in wall. The small flex

provided with this kit allows connection to the

Pellet Stove combustion air inlet. Note that

when installing the Wall Thimble Air Intake

Kit, the pipe will not be centered within the

framed opening. Loosely assemble both

halves of the Wall Thimble onto Pipe Section.

PELLET VENT

PRO PIPE

Advertising