adapter or connector going into the ceiling

support box.

B. Visually inspect with a flashlight the

condition of the interior of the chimney

for cleanliness and structural integrity. All

evidence of soot and creosote must be

removed from the existing chimney system.

If you doubt your ability to accomplish this,

contact a certified chimney sweep. Do not

use chemical cleaners, as these can possibly

damage the inside of the chimney. Do any

required maintenance on the existing chimney

system at this time.

C. Install a DVL/DuraBlack Chimney Adapter -

product stock numbers (6”) 8674, (7”) 8774, or

(8”) 8874 - in the existing Ceiling Support Box.

Note that the DVL/DuraBlack Chimney Adapter

only connects to Dura-Vent chimney systems.

D. Connect the appropriate size Chimney

Adapter to the DVL/DuraBlack Chimney

Adapter.

E. Connect the appliance to the Chimney

Adapter using an Appliance Adapter, lengths

of pipe as required, and an Adjustable Length

pipe. Slide the Adjustable Length down over

the top pipe section, position the installation

vertically plumb, then slip the Adjustable

Length up and twist lock it to the Chimney

Adapter. Once all the components are firmly

seated and properly aligned, carefully drill

three 1/8” diameter holes through the outer

sleeve only in the center of the slots located

at the bottom of the Adjustable Length pipe.

Do not penetrate the inner liner. Use (3)

1/4” length sheet metal screws to secure the

Adjustable Length pipe.