DuraVent Venting System For Direct Vent Pro User Manual

Page 8

Advertising
background image

8

pipe is permissible if allowed by the

appliance manufacturer.

Notes:

(1) The horizontal run of venting

must be level, or have a 1/4-inch rise

for every 1-foot of run towards the

termination. Never allow the vent to run

downward. A downward slope can trap

heat and become a possible fire hazard.

(2) The location of the Horizontal Vent

Termination on an exterior wall must

meet all local and national building

codes, and must not be easily blocked

or obstructed. Termination clearances

are as follows:

(a) Clearance above the ground,

veranda, porch, deck, or balcony: 12

inches minimum.

(b) Clearance to a window (operable

or fixed closed) or door: 12 inches

minimum.

(c) Vertical clearance to a ventilated

soffit located above the Termination Cap

(if soffit extends a horizontal distance

of 2 feet out over the centerline of the

termination): 18 inches minimum.

(d) Clearance to an unventilated soffit:

12 inches minimum.

(e) Clearance to an outside corner: as

tested by appliance manufacturer.

(f) Clearance to an inside corner: as

tested by appliance manufacturer.

(g) Not to be installed above a meter/

regulator assembly within 3 feet

TABLE 1

DIRECTVENT PRO FRAMING OR CUTOUT DIMENSIONS

STOCK NUMBER

COMPONENT DESCRIPTION

SIzE

46DVA-WT

Wall Thimble

10”x 10”

46DVA-WTS

Wall Thimble (Small)

9”x 9”

46DVA-WTU

Wall Thimble Universal

9”x 9”

46DVA-CS

Ceiling Support

10-3/4”x 10-3/4”

46DVA-FS

Fire Stop

9”x 9”

46DVA-WFS

Wall Fire Stop

10”x 10”

46DVA-VSS

Vinyl Siding Standoff

17”x 17”

46DVA-CF

Counter Flashing (Assembled)

13-1/2”x 13-1/2”

46DVA-CFK

Counter Flashing (4pc.Kit)

13-1/2”x 13-1/2”

46DVA-CFKS

Counter Flashing (Kit Small)

10-1/2”x 10-1/2”

46DVA-VSK

Vinyl Siding Standoff (4 Pc.Kit)

13-1/2”x 13-1/2”

46DVA-VSKS

Vinyl Siding Standoff (Kit Small)

10-1/2”x 10-1/2”

46DVA-IS

Insulation Shield

9”x 9”

58DVA-WT

Wall Thimble

10-1/2”x 10-1/2”

58DVA-WTS

Wall Thimble (Small)

9”x 9”

58DVA-WTU

Wall Thimble Universal

9”x 9”

58DVA-CS

Ceiling Support

10-3/4”x 10-3/4”

58DVA-FS

Fire Stop

10-1/2”x 10-1/2”

58DVA-WFS

Wall Fire Stop

10-1/2”x 10-1/2”

58DVA-VSS

Vinyl Siding Standoff

19-1/2”x 19-1/2”

56DVA-VSK

Vinyl Siding Standoff (4 Pc.Kit)

16”x 16”

58DVA-CF

Counter Flashing (Assembled)

16”x 16”

58DVA-CFK

Counter Flashing (4pc.Kit)

16”x 16”

58DVA-IS

Insulation Shield

11”x 11”

Advertising