4. Design and function

4.1 Description

By means of a sensor element and by supplying power, the prevailing pressure is converted into a

switching signal or an amplified standardised electrical signal via the deformation of a diaphragm. This

electrical signal varies in proportion to the pressure and can be evaluated accordingly.

PSD-30: Process connection with internal diaphragm (standard version).

PSD-31: Process connection with flush diaphragm for highly viscous or crystallising media that may clog

the bore of the process connection.

4.2 Scope of delivery

Cross-check the scope of delivery with the delivery note.

For flush design (model PSD-31) with pre-mounted sealings and protection cap.

5. Transport, packaging and storage

For the protection of the diaphragm, the flush design (model PSD-31) is delivered with a

special protection cap.

■

In order to avoid damage at the diaphragm and/or the process connection thread,

remove the protection cap by hand only just before installation.

■

Keep the protection cap for subsequent storage or transport.

■

Fit the protection cap before dismounting and transporting the instrument.

5.1 Transport

Check the instrument for any damage that may have been caused by transport. With flush design

(model PSD-31), additionally check the diaphragm for any optical damage.

Obvious damage must be reported immediately.