Specifications – WIKA S-11 User Manual
Page 14
Advertising

14
WIKA operating instructions pressure transmitter, model S-11
GB
14043046.01 06/2012 GB/D/F/E
3.7 Process connections
Process connection
Available measuring ranges
G ½ B flush
1)
0 ... 2.5 to 0 ... 600 bar
G 1 B flush
1)
0 ... 0.1 to 0 ... 1.6 bar
Hygienic G 1 B flush
0 ... 0.1 to 0 ... 25 bar
3.8 Materials
Wetted parts
■
Stainless steel
■
For sealing materials see table
Process connection
Standard
Option
without cooling element
NBR
■
FPM/FKM
■
EPDM
with cooling element
FPM/FKM
EPDM
Hygienic
EPDM
-
Non-wetted parts
Internal system fill fluid
■
Standard: Synthetic oil
■
Option:
Food-compatible system fill fluid per FDA 21 CFR 178.3750
3.9 Approvals, directives and certificates
Approval
■
CSA
■
GOST
3. Specifications