15

Permissible vibration load at the installation site

■

The instruments should always be installed in locations free from

vibration.

■

If the pipe to the gauge is not rigid enough for a vibration-free

installation, the gauge should be mounted by means of mounting

devices for surface or pipe mounting, and, if necessary, with a capillary.

■

If necessary, it is possible to isolate the instrument from the mounting

point by installing a flexible connection line between the measuring

point and the pressure gauge and mounting the instrument on a suitable

bracket.

■

If this is not possible, the following limit values must not be exceeded:

Frequency range < 150 Hz

Acceleration < 0.5 g (5 m/s

2

)

Commissioning

During the commissioning process pressure surges must be avoided at all

costs. Open the shut-off valves slowly.

8. Maintenance and cleaning

8.1 Maintenance

■

The instruments are maintenance-free.

■

The indicator and switching function should be checked once or twice

every year. The gauge must be disconnected from the process to check

with a pressure testing device.

■

Repairs are only to be carried out by the manufacturer or appropriately

trained skilled personnel.

7. Commissioning, operation / 8. Maintenance and cleaning